Black Box 34336, MD885AE-R2 S Register Functions, Register Range Units Default Description

Models: MD885C-R2 MD885A-R3 MD885AE-R2 34336

1 150
Download 150 pages 42.44 Kb
Page 107
Image 107

Modem 34336

Table 5-3. S Register Functions.

(Only registers intended for user access are listed.)

REGISTER

RANGE

UNITS

DEFAULT

DESCRIPTION

 

 

 

 

 

S0

0-255

rings

1

Ring to answer on

 

 

 

 

 

S1

0-255

rings

0

Counts number of rings

 

 

 

 

 

S2

0-127

ASCII

43

Escape-code character

 

 

 

 

 

S3

0-127

ASCII

13

Carriage-return character

 

 

 

 

 

S4

0-127

ASCII

10

Line-feed character

 

 

 

 

 

S5

0-127

ASCII

8

Backspace character

 

 

 

 

 

S6

2-255

sec

2

Wait time before blind

 

 

 

 

dialing

 

 

 

 

 

S7

1-60

sec

30

Wait time for carrier or

 

 

 

 

dial tone

 

 

 

 

 

S8

0-255

sec

2

Pause time for comma

 

 

 

 

 

S9

1-255

1/10 sec

6

Carrier-detect response

 

 

 

 

time

 

 

 

 

 

S10

1-255

1/10 sec

14

Delay time between loss

 

 

 

 

of carrier and hang-up

 

 

 

 

 

S11

70-255

ms

70

Tone spacing

 

 

 

 

 

S12

0-255

1/50 sec

50

Escape code guard time

 

 

 

 

 

S18

0-255

sec

0

Test timer

 

 

 

 

 

S25

0-255

sec or

 

Delay to DTR1

 

 

1/100 sec

5

 

S26

0-255

1/100 sec

0

RTS-to-CTS delay (half

 

 

 

 

duplex)

 

 

 

 

 

1Depends on mode; see previous section, S25 - DELAY TO DTR.

 

 

 

 

 