CHAPTER 4: Configuration

CHAPTER 4: Configuration

Table 4-3. DIP-switch SW3 settings.

Switch

Switch

Port

Description

 

RS-485

RS-422

Setting

Number

 

 

 

 

 

 

 

 

 

 

 

 

 

485

SW3-1

1

485

Mode (4-wire)

ON

OFF

 

NE

SW3-2

1

485 Mode, No Echo (2-wire)

ON

OFF

 

485

SW3-3

2

485

Mode (4-wire)

ON

OFF

 

NE

SW3-4

2

485 Mode, No Echo (2-wire)

ON

OFF

 

 

 

 

 

 

 

 

 

NE = No Echo. In a two-wire setup, the receiver will not echo back the transmitted

data.

4.2.2 QUAD-PORTUSB HUB—RS-422/485 (IC1021A)

Each of the four DB9 ports on the Quad-Port USB Hub can be set as either RS-422 or RS-485. You do not need to set a jumper to select these options. Instead, you just need to set DIP-switches SW1, SW2, SW3, and SW4.

Switch SW2 and SW4 Settings

To select either RS-422 or RS-485, set the DIP switches labeled SW2 and SW4 on the circuit board (see Figure 4-3). Table 4-4 lists the possible settings for DIP- switches SW2 and SW4. You can also set termination, pull-up resistance, and pull- down resistance via these switches.

Figure 4-3. Switches SW2 and SW4.

NOTE

Switch positions SW4-1, 2, 3, 4, and 5 are for Port 1. Switch positions SW4-6, 7, 8, 9, and 10 are for Port 2. Switch positions SW2-1, 2, 3, 4, and 5 are for Port 3. Switch positions SW2-6, 7, 8, 9, and 10 are for Port 4.

15

Page 16
Image 16
Black Box RS-232/422/485, RS422/485 Configuration, Port, Description, RS-485, RS-422, Switch SW2 and SW4 Settings