CHAPTER 4: Configuration

Figure 4-4. RS-422/485 interface configuration.

NOTE

Switch positions SW3-1 and 2 are for Port 1, SW3-3 and 4 are for Port 2,

SW1-1 and 2 are for Port 3, and SW1-3 and 4 are for Port 4.

Table 4-5. DIP-switch SW1 and SW3 settings.

Switch

Switch

Port

Description

 

 

RS-485

RS-422

Setting

Number

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

485

SW1-1

3

485

Mode (4-wire)

 

ON

OFF

 

NE

SW1-2

3

485

Mode, No Echo (2-wire)

ON

 

OFF

 

485

SW1-3

4

485

Mode (4-wire)

 

ON

OFF

 

NE

SW1-4

4

485

Mode, No Echo (2-wire)

ON

 

OFF

 

485

SW3-1

1

485

Mode (4-wire)

 

ON

OFF

 

NE

SW3-2

1

485

Mode, No Echo (2-wire)

ON

 

OFF

 

485

SW3-3

2

485

Mode (4-wire)

 

ON

OFF

 

NE

SW3-4

2

485

Mode, No Echo (2-wire)

ON

 

OFF

 

 

 

 

 

 

 

 

 

 

NE = No Echo. In a two-wire setup, the receiver will echo back all transmitted data.

4.2.3 QUAD-PORTUSB HUB—RS-232/422/485 (IC1022A)

You have a variety of configuration options for the four DB9 ports on the Quad- Port USB Hub. You can set all ports as RS-232, all ports as RS-422, all ports as RS- 485, or any combination of these interfaces. You also need to select termination (ON or OFF) for each port, and pull-up and pull-down resistors (ON or OFF) for

17

Page 18
Image 18
Black Box RS422/485 manual Port Description RS-485, QUAD-PORTUSB HUB-RS-232/422/485 IC1022A