Chapter 5: Operation
5. Operation
Download of DDC Information
By default, data from the internal DDC list is reported to the source (computer, CPU). If these settings do not lead to a satisfying result, you can download and store the console monitor’s DDC information internally. The devices must be configured accordingly (see Section 4.2).
On all KVM Extenders with
1.Enter Command Mode with the “hotkey” (see Section 4.2).
2.Press the <a> key to download the DDC information of the console monitor.
The screen goes black for a short time. Status LEDs on both CON and then CPU modules will flash to indicate the copy and store process.
At the same time Command Mode is closed and the keyboard LEDs return to previous status.
This
The DDC information of the console monitor was loaded once.
To
Page 42 | ACX1MT | |
|
|