Chapter 1: Specifications
Table 1-3. Digital audio interface specifications.
Specification | Description |
|
|
Compatibility | AES/EBU, S/PDIF, EIAJCP1201, IEC 60958 |
|
|
Standards | Dolby digital, DTS, PCM |
|
|
| • Mini XLR (AES/EBU; symmetrical lockable) |
CPU Unit (Inputs) | • Coaxial (S/PDIF; RCA, Cinch) |
| • Optical (S/PDIF, TOSLINK®) |
|
|
| • Mini XLR (AES/EBU; symmetrical, lockable) |
CON Unit (Outputs) | • Coaxial (S/PDIF, RCA, Cinch |
| • Optical (S/PDIF, TOSLINK) |
|
|
1.2 Interconnect Cable
1.2.1 CATx
NOTE: A
•Avoid routing CATx cables along power cables.
•If the site has
CAUTION: To maintain regulatory EMC compliance, you must use correctly installed shielded CATx cable throughout the interconnection link. Also, all CATx cables need to have ferrites on both cable ends close to the device.
Type of Interconnect Cable
The DKM Modular Extender requires interconnect cabling specified for Gigabit Ethernet
Table 1-4. CATx interconnect cable specifications.
ParameterDescription
S/UTP (CAT5e) cable according to
CATx
S/UTP (CAT5e) cable according to
CATx patch cable 26/8 AWG 26/8 AWG wires. Connection according to
NOTE: You can use flexible cables (patch cables) type 26/8 AWG; however, but you’ll only get half the maximum possible extension distance (Table
ACX1MT | Page 11 | |
|
|