The settings for these vehicle types have already been programmed.

Press the DEQ button ?.

Press the or button 7 repeat- edly until “CAR PRESETS” ap- pears in the display.

Press the OK button :.

Repeatedly press the or button 7 until the vehicle type that you want is displayed.

Press the DEQ button ?.

The settings are saved.

Automatic equalizer calibration (only Acapulco MP54)

You can electronically calibrate and store values for three different situations, e.g.:

EQ 1 for the driver only

EQ 2 for the driver and front passen- ger

EQ 3 for the front and rear occupants

Hold the calibration microphone in the appropriate position whilst calibration is taking place.

The position of the calibration micro- phone for Situation 1 (e.g. for the driver alone) is at the height of the driver’s head, approx. 10 cm next to the right ear.

For Situation 2, the calibration micro- phone should be positioned at head height between the driver and the front passenger.

For Situation 3, you should position the calibration microphone at head height in the centre of the vehicle interior (left/ right, front/rear).

EQUALIZER

Really quiet surroundings are required

for the calibration. Any extraneous noise

DEUTSCH

 

will distort the measured values.

 

The windows, doors and sunroof must

 

remain closed during the calibration

 

 

 

 

process. You should be seated in the

 

ENGLISH

driving seat throughout this procedure.

 

 

 

Note:

 

 

You can obtain the calibration micro-

 

 

 

 

 

phone necessary for this from acces-

 

 

FRANÇAIS

During calibration, the temperature in-

 

 

sory retailers.

 

 

 

side the vehicle must not exceed 55 °C

 

 

 

 

 

since this could lead to falsified meas-

 

 

ITALIANO

urements.

 

 

 

 

 

 

The sound radiating from the loud-

 

 

 

speakers must not be obstructed by any

 

 

 

objects. All the loudspeakers must be

 

 

NEDERLANDS

To calibrate the automatic equalizer,

 

 

connected. The microphone must be

 

 

 

connected to the device.

 

 

 

press the DEQ button ?.

 

 

 

 

 

SVENSKA

Press the or button 7 repeat-

 

 

 

 

 

 

edly until “MANUAL EQ” appears in

 

the display.

 

Press the OK button :.

 

 

 

 

 

ESPAÑOL

edly until the equalizer that you

 

 

Press the or button 7 repeat-

 

 

 

want to calibrate (“USER EQ1”,

 

 

 

 

 

 

“USER EQ2” or “USER EQ3”) ap-

PORTUGUÊS

pears in the display.

 

Press the OK button : twice.

 

Press the ESC button 8.

 

 

Press the or button 7 repeat-

DANSK

edly until “AUTO EQ” appears in

 

the display.

 

 

 

 

 

 

35

Page 35
Image 35
Blaupunkt Acapulco MP54 US, Casablanca MP54 US operating instructions Automatic equalizer calibration only Acapulco MP54