3.0OPERATION (Continued)

THERMOSTAT

The thermostat selects the desired internal kettle operating temperature. The thermostat must be set at a desired setting in order for the burner to ignite.

For Reference:

 

 

DIAL SETTING

EC

EF

1

15

60

2

27

81

3

40

104

4

53

127

5

67

153

6

81

178

7

95

203

8

108

226

9

122

252

10

135

275

PRESSURE GAUGE

The pressure gauge indicates the internal operating pressure of the kettle. When cold, the gauge should point to the green vacuum zone. If it does not, refer to “Re-establishing Vacuum” section. Under normal operation with the kettle empty (thermostat set at 10 or 275EF) the pressure should reach 30 psi. When loaded the pressure may be considerably less.

SIGHT GLASS

The sight glass indicates the minimum and maximum water level within the kettle. If water level falls below minimum level more distilled water should be added. See “Adding Water” in Service section.

13

Page 13
Image 13
Blodgett KLT-G Series manual Thermostat, Dial Setting, Pressure Gauge, Sight Glass