Blodgett KLT-G Series Service General, Orifice Size, Natural, Propane, Dms #, Manifold Pressure

Models: KLT-G Series

1 38
Download 38 pages 38.84 Kb
Page 21
Image 21
6.0SERVICE

6.0SERVICE

GENERAL

When any difficulty arises always check that the unit has been connected to the gas supply type and voltage for which it was supplied. This can be done by examining the serial plate on the lower right side of the unit. It will list the gas type and voltage for which the unit was manufactured.

Wiring diagrams for the unit are located in a small envelope affixed to the side panel of left hand console.

 

 

 

Orifice Size

Unit

Total Input

Natural

Propane

KLT-20G

80,000 BTU/Hour

DMS # 19

(.166")

DMS # 30 (.125")

KLT-40G

100,000 BTU/Hour

DMS # 13

(.185")

DMS # 27 (.144")

KLT-60G

120,000 BTU/Hour

DMS # 7

(.201")

DMS # 23 (.154")

MANIFOLD PRESSURE

 

Natural Gas - 3.5 inches W.C.

LP Gas - 4 inches W.C.

ADJUSTMENTS

 

WARNING: Adjustments and service work may be performed only by a qualified technician who is experienced in, and knowledgeable with, the operation of commercial gas cooking equipment. To assure your confidence, contact your authorized service agency for reliable service, dependable advice or other assistance, and for genuine factory parts.

21

Page 21
Image 21
Blodgett KLT-G Series manual Service General, Orifice Size, Natural, Propane, Dms #, Manifold Pressure, Adjustments