3.0 OPERATION
WARNING: Live steam and accumulated hot water in the compartment may be released when the door is opened.
WARNING: An obstructed drain can cause personal injury or property damage.
CONTROLS
Main Power Switch
ON | - | The boiler will automatically fill and begin heating to the preset |
|
| temperature. |
OFF | - | The boiler will drain. |
DELIME | - | Closes the drain valve while CLR liquid is being poured into the |
|
| generator during the delime procedure. |
Ready Light | - | Indicates the temperature has reached 205°F and that the |
|
| steamer is ready to begin cooking. |
Cooking Light | - | Indicates that a cooking cycle is in progress. |
Timer | - | Set the cooking time (0 to 60 minutes). Steam cooking will begin |
|
| when the door is closed. The cooking cycle will be interrupted if |
|
| the door is opened during the cooking cycle; resume cooking by |
|
| closing the door. |
|
| When done, a buzzer sounds and steam supply to the cooking |
|
| chamber will cease. Turn the timer OFF to stop the buzzer. |
9