![QUALITY TIMER ADJUSTMENT](/images/new-backgrounds/61016/6101629x1.webp)
SERVICING INSTRUCTIONS (continued)
661 74415 9311 Single Satellite Brewer
QUALITY TIMER ADJUSTMENT
PRECAUTIONS: | Disconnect brewer from electric power. |
| Allow brewer to cool. |
FREQUENCY: | As required to adjust delivered volume |
TOOLS: | Phillips head screwdriver |
| Satellite or other container to calibrate volume |
1.Press HEATER ON/OFF switch to OFF. Disconnect brewer from electrical power.
2.Remove TOP PANEL. Operating controls are accessible through the top panel only.
3.Adjust the QUALITY TIMER setting.
Turn CLOCKWISE to increase time;
Turn
4.Replace TOP PANEL. Turn TANK HEATER switch ON. Reconnect brewer to electrical power.
Procedure is complete
CAUTION:
SHOCK HAZARD
Disconnect brewer from electric power before opening the access panel.
The QUALITY TIMER flashes the SATELLITE light at the end of the set interval to signal that the coffee has lost freshness. Discard the coffee in the satellite and either brew a fresh batch or clean the satellite for future use.
Quality time interval begins when the brew switch is pressed.
When the light is flashing, coffee will continue to be maintained at temperature until the satellite is removed from the brewer.
Removing the satellite for
5 seconds will reset the timer.