Bloomfield 9311 owner manual Quality Timer Adjustment, SERVICING INSTRUCTIONS continued

Models: 9311

1 24
Download 24 pages 7.43 Kb
Page 15
Image 15
QUALITY TIMER ADJUSTMENT

SERVICING INSTRUCTIONS (continued)

661 74415 9311 Single Satellite Brewer

QUALITY TIMER ADJUSTMENT

PRECAUTIONS:

Disconnect brewer from electric power.

 

Allow brewer to cool.

FREQUENCY:

As required to adjust delivered volume

TOOLS:

Phillips head screwdriver

 

Satellite or other container to calibrate volume

1.Press HEATER ON/OFF switch to OFF. Disconnect brewer from electrical power.

2.Remove TOP PANEL. Operating controls are accessible through the top panel only.

3.Adjust the QUALITY TIMER setting.

Turn CLOCKWISE to increase time;

Turn COUNTER-CLOCKWISEto decrease time. Adjustment range is from 30 to 120 minutes.

4.Replace TOP PANEL. Turn TANK HEATER switch ON. Reconnect brewer to electrical power.

Procedure is complete

CAUTION:

SHOCK HAZARD

Disconnect brewer from electric power before opening the access panel.

The QUALITY TIMER flashes the SATELLITE light at the end of the set interval to signal that the coffee has lost freshness. Discard the coffee in the satellite and either brew a fresh batch or clean the satellite for future use.

Quality time interval begins when the brew switch is pressed.

When the light is flashing, coffee will continue to be maintained at temperature until the satellite is removed from the brewer.

Removing the satellite for

5 seconds will reset the timer.

13

Page 15
Image 15
Bloomfield 9311 owner manual Quality Timer Adjustment, SERVICING INSTRUCTIONS continued