Bloomfield 9311 owner manual Troubleshooting Suggestions, Brewer

Models: 9311

1 24
Download 24 pages 7.43 Kb
Page 18
Image 18
TROUBLESHOOTING SUGGESTIONS

 

 

 

 

 

 

 

 

 

 

 

 

 

TROUBLESHOOTING SUGGESTIONS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SYMPTOM

POSSIBLE CAUSE

SUGGESTED REMEDY

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Will not heat or brew

Brewer not plugged in or circuit

Reconnect brewer to electric power

 

 

 

 

 

(no lights)

breaker tripped

Reset circuit breaker

 

 

 

 

 

 

Fuse blown

Check satellite for water saturation

 

 

 

 

 

 

 

 

 

 

Replace fuse

 

 

 

 

 

 

Will not brew

Satellite is not in proper position

Reinstall satellite. Satellite light should

 

 

 

 

 

 

 

 

 

 

be on

 

 

 

 

 

 

 

Brew switch damaged

Check. Replace if needed

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Timer damaged

Check. Replace if needed

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Volume selector switch damaged

Check. Replace if needed

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Satellite connector snap-action

Check. Replace if needed

 

 

 

 

 

 

 

switch damaged

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Brewer fails to heat

Tank heat switch off

Turn tank heat switch on

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Hi-limit tripped

Allow to cool, reset hi-limit

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Thermostat out of adjustment or

Check. Adjust or replace as needed

 

 

 

 

 

 

 

damaged

 

 

 

 

 

 

 

 

Satellite receptacle or brewer

Check connectors. Be sure all pins are

 

 

 

 

 

 

 

connector damaged

in place and tight. Replace if needed

 

 

 

 

 

 

Brewer fails to stop

Switch not pressed long enough

Switch must be pressed firmly for at

 

 

 

 

 

 

brewing after STOP

or firmly enough

least 1 second

 

 

 

 

 

 

switch pressed

Stop Brew switch damaged

Check. Replace if needed

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Brew solenoid damaged or dirty

Check. Clean or replace as needed

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Coffee overflows from

Too much coffee or too fine a

Use proper amount and grind of coffee

 

 

 

 

 

 

brew chamber

grind

grounds per brew

 

 

 

 

 

 

 

More than 1 filter paper or wrong

Use 1 genuine Bloomfield filter paper

 

 

661

 

 

 

type of filter paper used

per brew

 

 

 

 

 

Timer out of adjustment or

Check time. Adjust or replace as

 

 

74415

 

 

 

damaged

needed

 

 

 

 

 

Brew solenoid damaged

Check. Replace if needed

 

 

9311

 

 

 

 

 

 

 

 

 

 

 

 

Wire rack missing from brew

Check. Replace if needed

 

 

 

Single

 

 

 

chamber

 

 

 

 

 

 

Insufficient brew volume

Low inlet water pressure

Other appliances on water line may be

 

 

 

Satellite

 

 

 

 

 

 

 

 

(all volumes)

 

 

 

robbing pressure. Brewer should be on

 

 

 

 

 

 

 

 

 

 

dedicated water line

 

 

 

Brewer

 

 

 

Inlet strainer plugged

Clean strainer

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Timers out of adjustment

Adjust time for each brew volume

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Timer damaged

Check. Replace if needed

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Satellite overflows

Bypass solenoid damaged

Check. Replace if needed

 

 

 

 

 

 

(1-1/2 gal brew only)

 

 

 

 

 

 

 

 

 

 

 

16

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Page 18
Image 18
Bloomfield 9311 owner manual Troubleshooting Suggestions, Brewer