Appliance details

Recommended exhaust vent terminator position

Fig. 16

Ref.

Description

Minimum distance

 

 

 

A

Directly below an opening; operable windows, doors and any non-

36 in

mechanical fresh air openings

 

 

 

 

 

 

Below a gutter, sanitary pipework or eaves

24 in

B

Below a gutter, sanitary pipework or eaves, protected by metal

12 in

 

shielding

 

 

 

 

 

C

From any internal corner

12 in

D*

Above ground

12 in

 

 

Above a paved sidewalk

7 ft

 

 

From an opposing wall or structure facing the termination

24 in

E

 

 

From any other building opening, gas utility meter, service regulator

36 in

 

 

or the like

 

 

 

 

 

F

From a terminator facing a terminator

48 in

G

Vertically between two exhaust vent terminators on the same wall

60 in

 

 

 

H

Horizontally between two exhaust vent terminators on the same wall

12 in

 

 

 

 

Horizontally from combustion air inlet of 250 SX

36 in

I**

 

Vertically above or below combustion air inlet of 250 SX

 

 

 

 

 

From the combustion air inlet of any other equipment

6 ft

J

From any external corner

12 in

K

Horizontally from an opening; operable windows, doors and any

12 in

non-mechanical fresh air openings

 

 

 

 

 

L

Vertically from a wall, roof slope, or obstruction (venting through a

see ABOVE THE ROOF

flat or pitched roof)

requirements on following page

 

 

 

 

Table 3

* Subject to local codes and anticipated snow level

** Other equipment that operates with a mechanical air inlet may require greater distances, reference manufacturer's instructions