Operation TS ��� 15

en

5.7Software update

The software update is performed either using the "ESI[tronic] Startcenter" DVD or "Online".

!!Only perform the software update for a licensed KTS 340. The USB link and the power supply to the KTS 340 must not be interrupted during the software update. In addition, Standby mode on the PC/laptop must be deactivated.

iiThe ESI[tronic] Startcenter DVD 1 (annual basic ver- sion) must be installed using the "Software update by way of DVD" function.

iiYou can find the online help for the software update in the ESI[tronic] Startcenter under "Help >> Help".

iiIf the software update of the KTS 340 was aborted (e.g. USB link was interrupted) or installation was incomplete, you can perform a recovery in the ESI[tronic] Startcenter under "Help >> Customer Service" in the menu "Restore KTS software" (see ESI[tronic] Startcenter online help).

5.7.1Online software update (from ESI[tronic] Startcenter version 2010/2)

1.Start the "ESI[tronic] Startcenter".

2.Open the "Settings >>Online updates" input box.

3.Enter the customer number and password and select <Next>.

iiIf "Login" is not possible, check proxy settings under "Settings >> User settings".

4.Select an available update and start the software update.

5.Follow the on-screen instructions.

iiTo successfully conclude installation, restart the PC/laptop.

KTS 340 software update

1. Disconnect the power supply unit and USB connect- ing cable from the KTS 340.

2. Start the "ESI[tronic] Startcenter".

3. Supply power to the KTS 340 once more with the power supply unit.

??The KTS 340 starts up.

??The start screen "Vehicle identification" appears.

4. Connect the KTS 340 to a PC/laptop by means of the USB connecting cable.

5. ESI[tronic] Startcenter: Open "KTS 340 >> Device information".

6. Select an available update

7. Select <Update>.

""The system software is installed on the KTS 340.

5.7.2Software update using the ESI[tronic] DVD

Step 1: Installing ESI[tronic] Startcenter

1.Close all open applications.

2.Insert the "ESI[tronic] Startcenter" DVD.

3.Open the "Windows Explorer".

4.Start D:\setup.exe (D = DVD drive).

??Setup commences.

5.Follow the on-screen instructions (see section 4.2.1).

iiTo successfully conclude installation, restart the PC/laptop.

Step 2: KTS 340 software update

1.Disconnect the power supply unit and USB connect- ing cable from the KTS 340.

2.Start the "ESI[tronic] Startcenter".

3.Supply power to the KTS 340 once more with the

power supply unit.

??The KTS 340 starts up.

??The "Vehicle identification" dialog box appears.

4.Connect the KTS 340 to a PC/laptop by means of the USB connecting cable.

5.ESI[tronic] Startcenter: Open "KTS 340 >> Device information".

6.Select an available update

iiIf no "available update" is displayed, the KTS 340 already has the current software and does not need to be updated.

7. Select <Update>.

""The system software is installed on the KTS 340.

5.8Faults

No communication with the control unit

The fault message "No system found" appears during control unit diagnosis.

Possible causes

Action to be taken

 

 

Incorrect cable

Check that the correct cable has been

connected.

used.

Wrong pin selected in

Check which pin must be used in "Diag-

pin selection menu.

nostic socket".

iiIf problems of a different nature occur, please con- tact the ESI[tronic] Service Hotline directly.