en 16 KTS 340 Maintenance
6.Maintenance
6.1Cleaning
Only clean the housing and display of the KTS 340 with a soft cloth and neutral cleaning agents. Do not use abrasive cleaning agents or coarse workshop cloths.
6.2Rechargeable battery replacement
Danger due to high voltage!
If the KTS 340 is open and the cover (Fig. 4, Pos. 5) of the LCD background illumination has been removed,
¶¶Never remove the cover of the background illumination.
Incorrect handling carries a risk of ignition, bursting or combustion!
Batteries must not be heated, burned, short- circuited, mechanically damaged or charged with excessively high currents or reverse polarity.
¶¶Suitable extinguishing agents: Water, CO2, sand.
!!Only use the
1.Switch off the KTS 340.
2.Slacken the screws (5x, Fig. 4, Pos. 1) on the back of the unit and detach the housing cover (Fig. 4, Pos. 2).
3.Take out the battery compartments on the left and right and set down on the metal housing (Fig. 4, Pos. 3).
4.Take out the old batteries (Fig. 4, Pos. 4).
5.Insert new batteries (8x), taking care to ensure correct polarity.
6.
!!Take care not to trap the leads to the battery com- partment when fitting the back panel.
7.
8.Screw the screws (5x) back in.
1
2
CH
BOS
4
5
3
4
3 | .axm |
| V28 |
Fig. 4: Rechargeable battery replacement
6.3Spare and wearing parts
Description | Order number |
|
|
System tester KTS 340 (green) | 1 687 023 549 |
Power supply unit | 1 687 022 890 |
Power supply lead | 1 684 461 161 |
USB connecting cable, 3 m | 1 684 465 562 |
OBD diagnostic cable, 3 m<) | 1 684 465 557 |
1 684 463 539 | |
Stylus (3x) | 1 683 083 007 |
Case | 1 685 438 626 |
Measuring lead, red<) | 1 684 430 065 |
Measuring lead, blue<) | 1 684 430 066 |
Measuring lead, yellow<) | 1 684 430 067 |
Ground cable, black<) | 1 684 430 068 |
Test prod, red (2x)<) | 1 684 485 035 |
Connection terminal, black<) | 1 684 480 022 |
Adapter insert | 1 688 000 355 |
Batteries (8x) | 1 687 335 031 |
<) Wearing part |
|
1 689 989 072 | Robert Bosch LLC |