en 16 KTS 340 Maintenance

6.Maintenance

6.1Cleaning

Only clean the housing and display of the KTS 340 with a soft cloth and neutral cleaning agents. Do not use abrasive cleaning agents or coarse workshop cloths.

6.2Rechargeable battery replacement

Danger due to high voltage!

If the KTS 340 is open and the cover (Fig. 4, Pos. 5) of the LCD background illumination has been removed, life-threatening high volt- age may occur.

Never remove the cover of the background illumination.

Incorrect handling carries a risk of ignition, bursting or combustion!

Batteries must not be heated, burned, short- circuited, mechanically damaged or charged with excessively high currents or reverse polarity.

Suitable extinguishing agents: Water, CO2, sand.

!!Only use the nickel-metal hydride batteries specified for the KTS 340. We recommend batteries with a battery capacity of 2000 mAh to 2300 mAh. Always replace all the batteries. Dispose of old batteries in accordance with the applicable legislation.

1.Switch off the KTS 340.

2.Slacken the screws (5x, Fig. 4, Pos. 1) on the back of the unit and detach the housing cover (Fig. 4, Pos. 2).

3.Take out the battery compartments on the left and right and set down on the metal housing (Fig. 4, Pos. 3).

4.Take out the old batteries (Fig. 4, Pos. 4).

5.Insert new batteries (8x), taking care to ensure correct polarity.

6.Re-insert the battery compartments in the unit.

!!Take care not to trap the leads to the battery com- partment when fitting the back panel.

7.Re-fit the back panel of the unit.

8.Screw the screws (5x) back in.

1

2

CH

BOS

4

5

3

4

3

.axm

 

V28

-3Ko 459843

Fig. 4: Rechargeable battery replacement

6.3Spare and wearing parts

Description

Order number

 

 

System tester KTS 340 (green)

1 687 023 549

Power supply unit

1 687 022 890

Power supply lead

1 684 461 161

USB connecting cable, 3 m

1 684 465 562

OBD diagnostic cable, 3 m<)

1 684 465 557

4-pole UNI connecting cable<)

1 684 463 539

Stylus (3x)

1 683 083 007

Case

1 685 438 626

Measuring lead, red<)

1 684 430 065

Measuring lead, blue<)

1 684 430 066

Measuring lead, yellow<)

1 684 430 067

Ground cable, black<)

1 684 430 068

Test prod, red (2x)<)

1 684 485 035

Connection terminal, black<)

1 684 480 022

Adapter insert

1 688 000 355

Batteries (8x)

1 687 335 031

<) Wearing part

 

1 689 989 072 2010-04-06

Robert Bosch LLC

Page 16