Technical data TS

17

 

en

 

 

 

 

 

7.Technical data

7.1

General data

 

 

 

 

Property

 

Value/Range

 

 

Operating voltage

11 VDC — 34 VDC

Power consumption

approx. 50 W

LCD

 

8.4"

 

 

800 x 600 pixels

Dimensions (L x W x H)

235 x 290 x 67 mm

 

 

9.25 x 11.42 x 2.64 inch

 

 

Weight (without connecting cables)

2100 g

 

 

4.6 lb

Operating temperature

5 °C – 40 °C

 

 

41 °F – 104 °F

Relative humidity

90 % (at 25 °C)

Degree of protection

IP 40

7.2Interface protocols

The following interfaces and their associated protocols are supported for control unit diagnosis in compliance with ISO 15031:

RR ISO/DIS 15765-4 (CAN) - baud rates: 250 kbit/s and 500 kbit/s)

RR ISO 9141-2 Fast

RR ISO/DIS 14230-4 (keyword protocol 2000) 5 bauds RR ISO/DIS 14230-4 (keyword protocol 2000) Fast

RR ISO/DIS 11519-4 (SAE J1850) PWM

RR ISO/DIS 11519-4 (SAE J1850) VPW

7.3Power supply unit

Property

Value/Range

 

 

Input voltage

100 VAC — 240 VAC

 

 

 

Input frequency

50

Hz — 60 Hz

 

 

 

Output voltage

15

V

 

 

Operating temperature

0 °C — 40 °C

 

 

 

7.4Multimeter specifications

RR CH1 zero potential (blue input may be connected to live measurement points). Input resistance

> 900 kohms.

RR CH2 non-floating (black ground input must be connected to vehicle ground). Input resistance > 900 kohms.

7.4.1DC measurement (CH1 and CH2)

Property

Value/Range

 

 

Measuring range

200 mV — 60 V

Accuracy of CH1

±0.75 % of measured value,

 

plus ±0.25 % of measuring range

Accuracy of CH2

±2 % of measured value,

 

plus ±0.5 % of measuring range

Resolution

100 µV — 100 mV

 

(depending on measuring range)

7.4.2Measurement of AC and rms value (CH1 and CH2)*)

Property

Value/Range

 

 

AC frequency range

10 Hz — 400 Hz (-3 dB)

Measuring range

200 mV — 60 V

AC accuracy at 100 Hz

±2 % of measured value, plus

rms accuracy at ≤ 100 H

±0.5 % of measuring range

 

Resolution

100 µV — 100 mV (depending

 

on measuring range)

*)

The measuring ranges in measurement modes "U" and "I" are

 

specified as peak-to-peak values. Consequently, the digital

 

display box is "grayed out" if the set measuring range is briefly

 

exceeded (overload).

7.4.3Resistance measurement (CH1)

Property

Value/Range

 

 

Measuring range

100 — 1 M

Accuracy up to 200 K

±0.75 % of measured value

 

plus ±0.25 % of measuring ran-

 

ge

Accuracy up to 1 M

±2 % of measured value

 

plus ±0.25 % of measuring ran-

 

ge

Resolution

0.1 — 1000 (depending on

 

measuring range)

Input resistance

> 9 M

Robert Bosch LLC

1 689 989 072 2010-04-06