MicroDome Camera 200 Series

Installation en 19

 

 

3.8Resetting the camera

If the camera cannot be connected because the IP address has changed, press and hold the reset button (7 seconds approximately) to recall the factory default values. The factory default IP address is 192.168.0.1

Figure 3.6 Reset button

3.9Closing the unit

When the camera position is set and all adjustments have been made, close the unit.

1.Remove the monitor cable from the jack socket.

2.If necessary, clean the inner surface of the dome with a soft cloth.

3.Position the dome on the base by aligning the two screw holders with fins with the openings beside the screw sockets and slot it home.

4.Use the supplied special screwdriver bit to tighten the three tamper-resistant screws.

Bosch Security Systems

Installation Manual

AR18-10-B012 v1.55 2012.09

Page 19
Image 19
Bosch Appliances NDC-274-PM, NDC-284-PT, NDC-274-PT installation manual Resetting the camera, Closing the unit