Bosch Appliances VDA-NWDFMT manual Attach mounting plate to backplate

Models: VDA-NWDFMT

1 22
Download 22 pages 36.98 Kb
Page 11
Image 11

Flush Mount Ceiling Kit

Installing the Recessed Camera Mount en

7

 

 

 

5.Loosen the three tamper-resistant screws in the FlexiDome IP Trim Ring (the screws remain in place) using a T20 pin- in Torx driver. Remove the Trim Ring with Dome

(Figure 2.2, item 4) by pulling it off of the base.

6.Remove the Inner Liner (Figure 2.2, item 3) by removing it from the Camera Module/Base.

7.Loosen the three Phillips head screws that secure the Camera Module/Base (Figure 2.2, item 2) to the Mounting Plate (Figure 2.2, item 1). Do not remove the hex-head screws.

8.Detach the safety tether. Set the Mounting Plate aside.

9.Remove the three screws securing the Recess Trim Ring to the Recess Bracket. Set the screws and the Recess Trim Ring aside.

10.Align the holes in the Recess Bracket and the Mounting Plate. Attach the Mounting Plate to the Recess Bracket, (item 5, below) using the three #10 Flat Washers and the three #10-24x1/2 in. Phillips Head Screws.

Figure 2.3 Attach mounting plate to backplate

11.Back the toggle bolts off the support screws until they are close to the end of the threads.

12.Run the power and the network cable (from the ceiling) through the slot in the Recess Bracket.

Bosch Security Systems, Inc.

Mounting Guide

F.01U.126.944 1.0 2009.04

Page 11
Image 11
Bosch Appliances VDA-NWDFMT manual Attach mounting plate to backplate