VideoJet X40 | Configuration Using a Web Browser en 55 |
|
|
Select the required recording type.
In the case of Ring mode the recording proceeds continuously. If the maximum hard drive space has been reached, the oldest recordings are automatically overwritten.
In the case of Linear mode the recording proceeds until the entire hard drive space is full. The recording is then stopped until old recordings have been deleted.
5.18.8Number of alarm tracks! | CAUTION! | |
Alarm tracks must be set up in the required partition for alarm recording. | ||
|
The unit uses a special recording mode during alarm recording for optimal usage of storage capacity: as soon as a time gap for alarm recording begins, a recording is continuously made on one segment, which is the size of a complete alarm sequence (pre- and
If the Ring mode option is set for the partition, the latest alarm recordings are always saved in the preset number. If the Linear mode option is selected for the partition, the recording is stopped as soon as the total number of alarm tracks has been recorded.
5.18.9 | Alarm track size | |
| The size for the alarm tracks can be calculated using various parameters. The calculated size | |
| applies for each of the alarm tracks. | |
| 1. | Click the Calculate button. A new window will open. |
| 2. | Select the setting you require from individual parameter list fields. |
| 3. | Click the Set button to apply the calculated value. |
Bosch Security Systems | Installation and Operating Manual | V3.5 2007.12 |