VideoJet X40 | Configuration Using a Web Browser en 73 |
|
|
If required, select a specific event that will trigger the relay. The following events are possible triggers:
–Off
Relay is not triggered by events
–Connection
Trigger whenever a connection is made
–Video alarm
Trigger by interruption of the video signal at the corresponding input
–Motion alarm
Trigger by motion alarm at the corresponding input, as configured on the VCA page (see Section 5.23 VCA, page 65)
–Local input
Trigger by the corresponding external alarm input
–Remote input
Trigger by remote station's corresponding switching contact (only if a connection exists)
NOTICE!
i The numbers in the lists of selectable events relate to the corresponding connections on the unit, Video alarm 1, for example to the Video In 1 connection.
5.26.4Relay nameYou can assign a name for the relay here. The name is shown on the button next to Trigger relay. The Livepage can also be configured to display the name under the relay icon.
5.26.5Trigger relayClick the button to trigger the relay manually (for testing or to operate a door opener, for example).
Bosch Security Systems | Installation and Operating Manual | V3.5 2007.12 |