Image 14

Trouble shooting

This section provides a list of the more frequently encountered malfunctions, their causes and corrective actions. The operator or maintenance personnel can perform some corrective actions, and others may require the assistance of a qualified Bosch technician or your dealer.

PROBLEM

SYMPTOMS

RESOLUTION

 

 

 

 

 

Excessive air tank

Pressure switch does not

Set the On/Off switch to Off, if the unit

pressure – safety

 

shut of motor when com-

 

does not shut off contact a Bosch fac-

valve pops off

 

pressor reaches cut-out

 

tory service center or a Bosch authorized

 

 

pressure

 

service center

 

Pressure switch cut-out

Contact a Bosch factory service center or

 

 

too high

 

a Bosch authorized service center

 

 

 

 

 

Air leaks

Tube fittings are not tight

Tighten fittings where air can be heard

 

 

enough

 

escaping. Check fittings with soapy water

 

 

 

 

solution. Do not overtighten.

Air leaks in air tank or

Defective air tank

Air tank must be replaced. Do not repair

at air tank welds

 

 

 

the leak

 

 

 

• Warning: Risk of bursting. Do not drill

 

 

 

 

into, weld or otherwise modify air tank or

 

 

 

 

it will weaken. The air tank can rupture or

 

 

 

 

explode.

Air leaks between

Leaking seals

Contact a Bosch factory service center or

head and valve plate

 

 

 

a Bosch authorized service center

Air leaks from safety

Defective safety valve

Operate safety valve manually by pull-

valve

 

 

 

ing on ring. If valve still leaks, it must be

 

 

 

 

replaced.

Knocking noise

Defective safety valve

Operate safety valve manually by pull-

 

 

 

 

ing on ring. If valve still leaks, it must be

 

Pump oil is low

 

replaced.

 

Add no-detergent oil to pump.

 

Carbon build-up in pump

Contact a Bosch factory service center or

 

 

 

 

a Bosch authorized service center

Pressure reading on

Regulator is not adjusted

It is normal for some pressure drop to

the regulated pressure

 

correctly for accessory

 

occur when an accessory is used, adjust

gauge drops when an

 

being used

 

the regulator.

accessory is used

 

 

Note: Adjust the regulated pressure

 

 

 

 

under flow conditions while accessory is

 

 

 

 

being used.