Choose whether the terminal sends data from the entire screen or from the scrolling region.

Ignore CTS: [Off, On]

Ignore CTS is not displayed in IBM 3151 emulations

Manual background Line Control: [CRTS, PRTS, IPRTS]

§PRTS* (permanent request to send) – PRTS handles the CTS and DSR signal as modem signals.

§IPRTS* (induced permanent request to send) – IPRTS handles the CTS and DSR signals as if the signals are always on.

§CRTS* (controlled request to send) – CRTS looks at the CTS, DSR and CD signals to determine when the terminal can send or receive data.

*PRTS and IPRTS require full duplex communication capabilities.

CRTS requires half duplex communication capabilities.

Manual background Turnaround Char: [<ETX>, <CR>, <EOT>, <DC3>]

The line turnaround character is attached to the end of a data stream when one of the read commands is received or one of the following keys is pressed:

Send

Send Line

Reset (if reset attn is enabled)

Clear

Print (if print key attn is enabled)

F1 thru F36

Print line (if print key attn is enabled)

PA1 thru PA3

Print Msg (if print key attn is enabled

Sn Msg

Manual background Send Null Suppress: [Off, On]

§Off – Trailing null characters are converted to space characters when data is sent to the host system.

§On – Trailing null characters are removed when data is sent to the host system.

PRINT: F8

Manual background Print Mode: [Normal, Auto, Controller]

Select the way in which printing is controlled.

§Normal – indicates that printing is to occur when a print request (such as print screen) is received.

§Auto – prints a line when the terminal receives a LF, a FF, or a VT code, or when autowrap occurs.

§Controller – indicates that host data is sent to the printer (pass through mode). Printing is controlled by the host computer.

Print Block Term: [<ETX>, <CR>]

Select the character which indicates to the printer that the block of data to be printed has ended. The options above are for ASCII emulations. In ANSI emulations, the choices are [None, <FF>].