APPENDIX
LAMP REPLACEMENT Indicator
When the Lamp of this projector draws to an end, the LAMP REPLACEMENT indicator lights yellow. When the image become dark or the color of the image becomes unnatural, replacement of the Lamp is required.
LAMP REPLACEMENT
CAUTION
●For continued safety, replace with a lamp assembly of the same type.
●Allow the projector to cool for at least 45 minutes before you open the lamp cover. The inside of the projector can become very hot.
●Do not drop the lamp assembly or touch the glass bulb! The glass can shatter and may cause injury.
Follow these steps to replace the lamp assembly.
1 | Turn off the projector and disconnect the AC plug. Allow the |
projector to cool for at least 45 minutes. | |
2 | Remove a screw with a screwdriver and remove the lamp cover. |
3 | Remove 2 screws with a screwdriver and pull out the lamp |
assembly by grasping the handle. | |
4 | Replace the Lamp Assembly and tighten 2 screws. Make sure |
that the Lamp Assembly is set properly. And replace the Lamp | |
| Cover and tighten a screw. |
5 | on.Connect the AC Power Cord to the projector and turn the projector |
6 | Reset the Lamp Replacement Monitor Timer (refer to the section |
“Lamp Replacement Monitor Timer” below.) |
NOTE : Do not reset the LAMP REPLACEMENT MONITOR TIMER, when the lamp is not replaced.
LAMP COVER
HANDLE
LAMP
ASSEMBLY
ORDER REPLACEMENT LAMP
Replacement Lamp can be ordered through Boxlight at
●Replacement Lamp Type No. :
(Service Parts No. 610 278 3896)
Lamp Replacement Monitor Timer
Be sure to reset the Lamp Replacement Monitor Timer when the Lamp Assembly is replaced. When the Lamp Replacement Monitor Timer is reset, the LAMP REPLACEMENT indicator stops to lighting.
1 | Turn the projector on, and press the MENU button and the | |
| LEFT/RIGHT buttons to select SETTING | and press the SELECT button (refer to the page 32). Another |
| dialog box SETTING MENU Menu will appear. |
|
2 | Press the POINT DOWN button and a | |
| SELECT button. The message of "Lamp replace monitor Reset?" is displayed. | |
3 | Select [Yes] to reset the Timer. |
|
Do not reset the Lamp Replacement Monitor Timer, except after the lamp is replaced.
35