SERVICE PROCEDURE
Gas Control Replacement Thermal
Well and Chamber Door Sensor
Testing and Replacement
Gas Control & Thermal Well Removal From Water Heater
Gas Control
Step 1. Turn the gas control knob to the “OFF” position.
Step 2. Drain heater to a point below the gas
control level.
Step 3. Turn off gas supply to water heater and disconnect gas piping from gas control.
Step 4. Disconnect wire harnesses and burner assembly from gas control.
Step 5. Remove gas control & thermal well by rotating flats of Thermal Well counter clockwise
Gas Control Removal From Thermal Well
Follow the steps below allows removal gas control from thermal well without removing thermal well from tank.
Step 1. Turn the gas control knob to the “OFF” position.
Step 2. Turn off gas supply to water heater and disconnect gas piping from gas control. Step 3. Disconnect wire harnesses & burner assembly from gas control.
Step 4. Using gas control service tool
View from back of control for clarity
Insert tool from | Service tool shown |
back of control | inserted in to back |
| of control |
Step 5. Pivot tool towards heater as far as possible (see photo below). Lift straight up on gas control. The control should move about 1/8". Hold control in position and remove tool. Lift straight up on control to remove completely from Thermal Well.
With service tool inserted, pivot tool back towards heater as far as possible. Lift straight up on control, control will move 1/8". Remove tool and continue to lift straight up on control to remove from Thermal Well.
Page 16
16