RESETTABLE THERMAL SWITCH REPLACEMENT

SERVICE PROCEDURE ED-VII

Resettable Thermal Switch

Testing and Replacement

RESETTABLE THERMAL SWITCH REPLACEMENT

Step 1. Rotate gas control knob to the “OFF” position.

Gas Control Knob Shown In

“OFF” Position

Step 2. Remove outer jacket door.

Step 3. Disconnect wire leads from resettable thermal switch.

Step 4. Remove (2) ¼” hex drive screws from the manifold mount.

Step 5. Bend the flexible feed line so the resettable thermal switch is easily accessible.

Step 6. Remove resettable thermal switch from manifold mount (Phillips screw driver).

Manifold Mount

Step 7. Place new resettable thermal switch in place. Be sure contact surface of resettable thermal switch and manifold mount are free of any debris. Secure resettable thermal switch into place using screws from step 6.

DO NOT OVER TIGHTEN SCREWS.

Step 8. Bend flexible feed line back in place and secure the manifold mount using the screws from step 4. Step 9. Reconnect wire leads from gas valve and thermopile to resettable thermal switch.

Note: Wire termination are interchangeable with either resettable thermal switch connection. Step 10. Replace outer jacket door.

Step 11. To resume operation follow the instructions located on the lighting instruction label or the lighting instruction located in the installation and operation manual.