Gas Control Troubleshooting
Observe red LED indicator on gas control. Error flash codes are displayed with a three second pause before repeating. Check and repair the system as noted in the troubleshooting table below.
Red LED Indicator
LED Status | Control Status | Probable Cause | Service Procedure |
|
| Gas valve is operating |
| If the pilot will not stay lit |
|
| normally. Pilot flame | 1. Gas valve is |
| |
None (LED not on | replace thermopile, see |
| ||
may not be present. | functioning normally |
| ||
page 10. If problem |
| |||
or flashing) | Check for pilot flame | 2. Gas valve is not |
| |
persists replace gas |
| |||
| through sight glass and | powered. Light pilot |
| |
| valve, see page 16. |
| ||
| light if necessary. |
|
| |
|
|
|
| |
One flash and | If set point knob is in | Gas valve is powered |
|
|
"PILOT" position then | and waiting for the set | Normal operation. Adjust |
| |
three second | pilot flame is detected. | point knob to be turned | thermostat to desired |
|
pause. | Turn set point knob to | to a water temperature | temperature level. |
|
| desired setting | setting. |
|
|
| Set point knob has |
|
|
|
LED on | been recently turned to | Set point knob was | LED will go out and the |
|
the "OFF" position. | turned to "OFF" | control will function |
| |
continuously. | Wait until LED goes out | normally when the pilot is |
| |
| before attempting to | position. | lit. |
|
|
|
| ||
| relight |
|
|
|
| Weak pilot flame | 1. Thermopile failure |
|
|
Two flashes and | 2. Unstable pilot. | 1. See page 10. |
| |
detected. System will | 3. Pilot tube block or |
| ||
three second | 2&3. See page 12. |
| ||
reset when pilot flame | restricted. |
| ||
pause. | 4. See page 21. |
| ||
is sufficient. | 4. Resettable thermal |
| ||
|
|
| ||
|
| switch has opened. |
|
|
Three flashes and | Insufficient water | 1. Thermowell sensor |
|
|
and chamber | 1&2. See pages 14 and |
| ||
three second | heating. System will | temperature sensor out |
| |
pause. | reset. | of calibration. | 18. |
|
|
| |||
|
| 2. Possible short. |
|
|
Four flashes and | Excessive tank | 1. Thermowell sensor | 1. See page 14. |
|
three second | temperature. System | out of calibration. |
| |
2. See page 16. |
| |||
pause. | must be reset. | 2. Faulty gas valve. |
| |
|
|
Page 5