Brute Mini Hydronic Boiler | Page 5 |
|
|
Dimensions in inches cm |
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
| Dimensions |
|
|
|
|
|
| Water | Gas |
|
|
|
|
|
| inches cm |
|
|
|
|
|
| Conn. | Conn. |
Size* | A |
| B |
| C |
| D |
| E |
|
| V | in. | in. |
50 | 34 | 71 | 60 | 55 | 67 | 4 | 10 | 1/2 | ||||||
75 | 34 | 71 | 61 | 55 | 70 | 5 | 13 | 1/2 | ||||||
100 | 43 | 73 | 61 | 58 | 70 | 5 | 13 | 1/2 | ||||||
125 | 43 | 73 | 60 | 58 | 70 | 6 | 15 | 1/2 | ||||||
160 | 52 | 73 | 60 | 58 | 70 | 6 | 15 | 1/2 | ||||||
225 | 65 | 80 | 59 | 63 | 70 | 7 | 18 | *3/4** | ||||||
* Values shown are for both BJVS and BJVT Models |
|
|
|
|
|
|
| **1/2 for propane |
Figure 1. Dimensional Information.
2.2 Field Assembly
1.Brute Mini boilers have
2.Find the vent damper box which is located in the boiler package.
3.Install the vent damper directly to the top of the draft diverter outlet with the damper operator facing to the front of the boiler, and with the flow direction arrow pointing upward. Use the vent damper wire harness provided with the boiler to connect the vent damper to the boiler. The bracket end of the harness should be connected to the vent damper actuator.
4.For Model BJVS only: Install the metal plug provided with the vent damper onto the damper plate hole. Disregard the metal plug in case of standing (continuous) pilot boilers. For all
BJVT models, the damper plate hole should never be blocked.
5.Do not modify the automatic vent damper device. It is very important that no other vents are closed. Provide at least six inches clearance between the automatic vent damper and combustible construction, and be sure to allow access for servicing the damper.
6.Install the temperature/pressure gauge provided in the parts box.