Brute Mini Hydronic Boiler | Page 31 |
|
|
Heat Distribution Units
Transfers heat from the water supplied by the boiler to the area to be heated through the use of baseboard, convector, radiator, finned tube. Also known as "radiation."
Isolation Valve
Used to isolate the boiler from the circuit. It minimizes the amount of water drained from the system.
Two or more interconnecting circulating loops, each with its own pump.
Reverse-return Piping
Balanced, equal flow (first in, last out) piping. Utilized with multiple boilers and/or radiation. Applied with single system pumps, or
Side Wall Power Venter
This accessory allows the boiler exhaust to be routed horizontally through an adjoining outside wall, rather than gravity venting with a chimney or stack when local codes allow.
System Purge Valve
A device used to purge air from the circuit. Should be located as close as possible to the cold water feed, but not immediately after the cold water feed.
Trunk
The section of piping which connects the boiler return and supply with the branch(es). Also known as a "main" or "header." Should be same size as boiler inlet/outlet connections.
Vent Damper (optional in Canada)
Standard on BJV boilers. This
Zone Pump
Circulators installed in branch piping that divert hot water coming from the boiler into various areas (zones) of a building.
Zone Valve
Diverts hot water from the boiler into various areas (zones) of a building.
SECTION 11.
Replacement Parts
11.1 Ordering Information
To order or purchase parts for the Brute Mini BJVS or BJVT boiler, contact your nearest Representative. If you need assistance in finding a local dealer or distributor, contact the Technical Service Department.
NOTE: To supply the correct part it is important that you state the model number, serial number and type of gas when applicable. This information is on the rating plate on the heater.
11.2 Parts List
The following pages contain a parts list and a general exploded view to aid in parts identification. Please refer to these pages when ordering parts for your BJVS or BJVT boiler.