| Troubleshooting |
|
|
|
|
Troubleshooting Guide |
|
|
|
Problem | Possible Cause | Possible Solution | |
Ramp/controller will not | Controller not configured | ||
respond or function to | properly |
|
|
inputs properly | Jumpers loose or fallen off | Inspect and replace jumpers in proper | |
| controller terminals | configuration | |
| Interlocks not installed/con- | Verify interlock signals are present as required | |
| nected correctly (Park, |
|
|
| Manual Release) |
|
|
| Controller relay failure | Inspect relays and replace if failed | |
| Electrical harness failure | Inspect harness and replace if failed | |
|
|
| |
Panel binds on front | Front cover edge is hitting the | Adjust stow height lower | |
cover during stowing | screws/nuts of the platform |
|
|
sequence | hinge assembly | Grind clearance for nuts | |
|
|
| |
Pressure mat will not | Controller not configured | ||
respond or function | properly |
|
|
properly |
|
|
|
| Electrical harness failure | Inspect harness and replace if failed | |
|
|
| |
Sensitivity edge will | Controller not configured | ||
not respond or function | properly |
|
|
properly |
|
|
|
| Electrical harness failure | Inspect harness and replace if failed | |
|
|
|
|
Page 25