KNOW YOUR GENERATOR

KNOW YOUR GENERATOR

Read this Operator’s Manual and safety rules before operating your generator.

Compare the illustrations with your generator, to familiarize yourself with the locations of various controls and adjustments. Save this manual for future reference.

Electric Start Button

Recoil Starter

Oil Fill Cap

Circuit Breakers (AC)

Fuel Tank

Ignition Switch

Idle Control Switch

12 Volt DC

 

Choke Lever

Receptacle

 

 

 

120 Volt AC, 20 Amp

 

 

Duplex Receptacles

 

 

120 Volt AC, 20 Amp

 

Air Cleaner

 

 

Locking Receptacle

 

 

 

 

Spark Arrester Muffler

120 Volt AC, 30 Amp

 

 

Locking Receptacle

 

240 Volt AC, 50 Amp

 

 

120/240 Volt AC, 30 Amp

Grounding

Receptacle

Data Tag

Locking Receptacle

Fastener

12 Volt DC Receptacle — Use this receptacle with battery charge cables to charge a 12 Volt battery.

120 Volt AC, 20 Amp Duplex Receptacles — May be used to supply electrical power for the operation of 120Volt AC, 20 Amp, single phase, 60 Hz electrical lighting, appliance, tool and motor loads.

120 Volt AC, 20 Amp Locking Receptacle — May be used to supply electrical power for the operation of 120Volt AC, 20 Amp, single phase, 60 Hz electrical lighting, appliance, tool and motor loads.

120 Volt AC, 30 Amp Locking Receptacle — May be used to supply electrical power for the operation of 120 Volt AC, 30 Amp, single phase, 60 Hz electrical lighting, appliance, tool and motor loads.

120/240 Volt AC, 30 Amp Locking Receptacle — May be used to supply electrical power for the operation of 120 and/or 240 Volt AC, 30 Amp, single phase, 60 Hz electrical lighting, appliance, tool and motor loads.

240 Volt AC, 50 Amp Receptacle — May be used to supply electrical power for the operation of 240 Volt AC, 50 Amp, single phase, 60 Hz electrical loads.

Air Cleaner — Protects engine by filtering dust and debris out of intake air.

Choke Lever — Used when starting a cold engine.

Circuit Breakers (AC) — Each receptacle is provided with a "push to reset" circuit breaker to protect the generator against electrical overload.

Data Tag – Provides model, revision and serial number of generator. Please have these readily available if calling for assistance.

Fuel Tank — Capacity of eight (8) U.S. gallons. Electric Start Switch — Press to start the engine.

Grounding Fastener — If required, please consult a qualified electrician, electrical inspector, or local agency having jurisdiction.

Idle Control Switch — The idle control runs the engine at normal (high) speeds when there is a load present and runs the engine at idle (low) speeds when a load is not present.

Oil Fill Cap — Add oil to engine here.

Recoil Starter — Used to start the engine manually.

Ignition Switch — Must be in “On(–) position to start engine. Set to “Off” (o) to stop a running engine.

Spark Arrester Muffler — Exhaust muffler lowers engine noise and is equipped with a spark arrester screen.