LP Fuel Tank Installation

IMPORTANT: To ensure optimal performance, use two (2) LP fuel tanks during operation.

This section describes the proper method of installing and leak testing the generator’s LP fuel tanks. This system is supplied with an LP fuel tank cover. Always cover the LP fuel tanks whenever they are connected to the generator.

WARNING

Propane Gas is extremely flammable and explosive.

Fire or explosion can cause severe burns or death.

The slightest spark can ignite this fuel and cause an explosion.

IF YOU SMELL GAS - Shut off gas to the generator at the LP fuel tank(s).

If odor continues, leave the area and immediately call your gas supplier or fire department.

To Install LP Fuel Tanks:

1.Confirm both LP fuel tank shut off valves are closed (turned fully CLOCKWISE).

2.Place each LP tank into the LP tank tray with it’s fuel valve pointing towards the generator (see Figure 5).

A

B

Figure 5 — Proper Position for LP Fuel Tanks

A - LP Fuel Tank Shut Off Valve Connector B - LP Fuel Tank

3.Slide the LP fuel tank hold-down bracket onto the threaded rod. Position the bracket so that its notches are aligned with both LP fuel tank collar holes, as shown in Figure 6.

A B

Figure 6 — Properly-Aligned Hold-Down Bracket

A - Bracket Notch over Fuel Tank Collar

B - Hold-Down Bracket

It may be necessary to “wiggle” the LP fuel tanks and the bracket to obtain proper alignment.

4.Slide the fuel hose/regulator assembly over the threaded rod so that it faces the generator and rests on the hold-down bracket (see Figure 7).

A B C

Figure 7 — Fuel Hose/Regulator Assembly Placement

A - Hold-Down Bracket

B - Threaded Rod

C - Fuel Hose/Regulator Assembly

5.Thread the wing nut CLOCKWISE onto the threaded rod. Hand tighten wing nut against fuel hose/regulator assembly, ensuring hold-down bracket notches remain engaged with LP fuel tank collars and LP fuel tanks are held firmly. See Figure 8.

A

B

C

Figure 8 — Properly-Secured LP Fuel Tanks

A - LP Fuel Tank

B - Wing Nut

C - Fuel Hose/Regulator Assembly

6.Remove protective covers from both LP fuel tank shut off valve connectors. DO NOT discard protective covers - they should be installed any time the LP fuel tank is disconnected from the generator.

7.Insert the nipple of the left connection device (as you face the generator and LP fuel tanks) into the left LP fuel tank valve outlet (see Figure 9). Ensure it is fully inserted.

8www.briggsandstratton.com

Page 10
Image 10
Briggs & Stratton 40248 manuel dutilisation To Install LP Fuel Tanks

40248 specifications

The Briggs & Stratton 40248 is a durable and efficient portable generator that has been designed to meet the demands of various outdoor activities, construction sites, and emergency backup power needs. With a reliable gasoline engine, the generator is capable of delivering solid performance in a wide range of applications.

One of the standout features of the Briggs & Stratton 40248 is its powerful 4500-watt surge and 3600-watt continuous output, providing ample power for essential appliances, tools, and equipment. This makes it an excellent choice for both recreational and emergency situations, ensuring that users have access to electricity when they need it most.

The generator is equipped with a reliable Ohv engine, known for its longevity and fuel efficiency. The 40248 includes a 3.5-gallon fuel tank, allowing for extended run times of up to 14 hours at a 25% load. This combination of powerful performance and efficient fuel consumption makes it an ideal option for long camping trips, outdoor events, or power outages.

In terms of portability, the Briggs & Stratton 40248 features an integrated handle and rugged wheels that make it easy to transport across various terrains. This enhanced mobility allows users to take the generator wherever it’s needed without hassle. Furthermore, its compact design ensures that it occupies minimal storage space.

Safety is a critical aspect of the Briggs & Stratton 40248, which includes features such as low oil shutdown to protect the engine from damage and overload protection to prevent equipment failure. These technologies ensure that your generator operates efficiently and safely, offering peace of mind to users.

The control panel is user-friendly, featuring multiple outlets including standard 120V outlets and a 12V automotive-style outlet, allowing for versatility in power options. This configuration makes it easy to connect various devices and enjoy uninterrupted power.

In summary, the Briggs & Stratton 40248 combines power, portability, and safety to deliver an outstanding generator for both recreational and emergency use. Its robust features, reliable engine, and user-oriented design make it a standout choice in the portable generator market, ensuring that users can meet their power needs confidently and conveniently. Whether powering tools on a job site or providing backup power during an outage, the 40248 excels in various environments.