Assembly/Installation

Your generator is ready for use after you assemble the LP fuel tank housing pad components, make proper fuel connections, and verify that engine oil is at the proper level.

CAUTION

Any attempt to crank or start the engine without verifying it has been properly serviced with the recommended oil will result in equipment failure.

Refer to Maintenance for oil fill information.

Damage to equipment resulting from failure to follow this instruction will void warranty.

If you have any problems with the assembly of your generator, please call the generator helpline at

1-800-743-4115. If calling for assistance, please have the model, revision, and serial number from the data tag available. See “Generator Controls and Features” for data tag location.

Shipment Contents

The generator is supplied with:

Generator pre-attached to mounting pad

LP fuel tank housing tray assembly pre-attached to mounting pad

Fuel hose and regulator assembly pre-attached to generator

LP fuel tank all-weather cover

Bag containing LP fuel tank attachment hardware

Operator’s manual

Battery

Oil drain tray

Touch-up paint

One spare 15A fuse

NG conversion kit

You must purchase two filled 20 pound DOT LP fuel tanks that are equipped with a listed over-filling prevention device (OPD).

Lifting the Generator

CAUTION The generator weighs more than

280 pounds (130 kg). Proper tools, equipment and qualified personnel should be used in all phases of handling and moving the generator. Each full LP tank will weigh more than 20 pounds (9 kg).

CAUTION DO NOT lift unit by roof as damage to generator will occur.

Lifting pockets are provided at each corner between the base of the generator and its mounting pad. See “Generator Controls and Features” for locations. Retouch any chipped paint with supplied touch-up paint.

Generator Location

Consider these factors when determining the proper generator operating location:

Install the unit outdoors on a flat, level surface with provisions for adequate ventilation. This will allow for dispersion of deadly exhaust gas. DO NOT install generator where exhaust gas could accumulate and enter inside or be drawn into a potentially occupied building areas.

Using a generator indoors WILL KILL YOU IN MINUTES.

Exhaust contains carbon monoxide, a poison gas you cannot see or smell.

NEVER use in the home ONLY use outdoors and

or in partly enclosed far from open windows, areas such as garages. doors, and vents.

Ensure exhaust gas is kept away from any windows, doors, ventilation intakes or other openings that can allow exhaust gas to collect in a confined area (Figure 1). Prevailing winds and air currents should be taken into consideration when positioning generator.

A

Figure 1 — Generator Clearances

A - Engine Exhaust Opening

The unit must have at least 5 ft. (152 cm) of clearance on all sides of the enclosure and LP tank housing pad, including overhead. This will reduce the risk of exhaust heat or exhaust gases igniting nearby combustible materials and will provide for adequate cooling and generator maintenance.

WARNING

Exhaust heat/gases can ignite combustibles, structures or damage LP fuel tank causing a fire.

Keep at least 5 ft. (152 cm) clearance on all sides of generator including overhead.

6www.briggsandstratton.com

Page 8
Image 8
Briggs & Stratton 40248 Assembly/Installation, Shipment Contents, Lifting the Generator, Generator Location

40248 specifications

The Briggs & Stratton 40248 is a durable and efficient portable generator that has been designed to meet the demands of various outdoor activities, construction sites, and emergency backup power needs. With a reliable gasoline engine, the generator is capable of delivering solid performance in a wide range of applications.

One of the standout features of the Briggs & Stratton 40248 is its powerful 4500-watt surge and 3600-watt continuous output, providing ample power for essential appliances, tools, and equipment. This makes it an excellent choice for both recreational and emergency situations, ensuring that users have access to electricity when they need it most.

The generator is equipped with a reliable Ohv engine, known for its longevity and fuel efficiency. The 40248 includes a 3.5-gallon fuel tank, allowing for extended run times of up to 14 hours at a 25% load. This combination of powerful performance and efficient fuel consumption makes it an ideal option for long camping trips, outdoor events, or power outages.

In terms of portability, the Briggs & Stratton 40248 features an integrated handle and rugged wheels that make it easy to transport across various terrains. This enhanced mobility allows users to take the generator wherever it’s needed without hassle. Furthermore, its compact design ensures that it occupies minimal storage space.

Safety is a critical aspect of the Briggs & Stratton 40248, which includes features such as low oil shutdown to protect the engine from damage and overload protection to prevent equipment failure. These technologies ensure that your generator operates efficiently and safely, offering peace of mind to users.

The control panel is user-friendly, featuring multiple outlets including standard 120V outlets and a 12V automotive-style outlet, allowing for versatility in power options. This configuration makes it easy to connect various devices and enjoy uninterrupted power.

In summary, the Briggs & Stratton 40248 combines power, portability, and safety to deliver an outstanding generator for both recreational and emergency use. Its robust features, reliable engine, and user-oriented design make it a standout choice in the portable generator market, ensuring that users can meet their power needs confidently and conveniently. Whether powering tools on a job site or providing backup power during an outage, the 40248 excels in various environments.