Image 19

Maintenance Schedule

Follow the hourly or calendar intervals, whichever occurs first.

More frequent service is required when operating in adverse conditions noted below.

MAINTENANCE SCHEDULE

 

SERVICE DATES

 

 

 

 

FILL IN DATES AS YOU

 

 

 

 

 

COMPLETE REGULAR SERVICE

 

 

 

 

SERVICE DATES

MAINTENANCE TASK

Before

Every 25 Hours

Every 50 Hours

Every 100 Hours

 

 

 

Each Use

or Yearly

or Yearly

or Yearly

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Clean debris

X

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Check oil level

X

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Change engine oil

 

 

X1

 

 

 

 

 

 

 

 

 

 

 

 

Change oil filter

 

 

 

X

 

 

 

 

 

 

 

 

 

 

 

Service air cleaner pre-cleaner

 

X²

 

 

 

 

 

 

 

 

 

 

 

 

 

Replace air cleaner cartridge

 

 

 

X²

 

 

 

 

 

 

 

 

 

 

 

Replace spark plug

 

 

 

X

 

 

 

 

 

 

 

 

 

 

 

Check valve clearance

 

 

 

X3

 

 

 

 

 

 

 

 

 

 

 

Clean cooling system

 

 

 

X4

 

 

 

 

 

 

 

 

 

 

 

Replace fuel hoses and regulator

 

 

 

X5

 

 

 

 

 

 

 

 

 

 

 

1Change oil sooner when operating under dirty or dusty conditions.

2Replace more often under dirty or dusty conditions.

3Check yearly only.

4Clean more often under dirty or dusty conditions.

5Replace every five years.

General Recommendations

Regular maintenance will improve the performance and extend the life of the generator. See any authorized Briggs

&Stratton dealer for service. Never operate a damaged or defective generator. To receive full value from the warranty, the operator must maintain the generator as instructed in this section.

All service and adjustments should be made at least once each season. Follow the requirements in the “Maintenance Schedule” chart above.

NOTE: Once a year you should clean or replace the spark plug and replace the air filter. A new spark plug and clean air filter assure proper fuel-air mixture and help your engine run better and last longer.

NOTE: The alternator assembly rotates on a prelubricated and sealed ball bearing that requires no additional lubrication for the life of the bearing.

Emissions Control

Maintenance, replacement or repair of the emissions control devices and systems may be performed by any non-road engine repair establishment or individual. See “Emissions Control System Warranty”.

Maintenance

Maintenance consists of keeping the unit clean. Operate the unit in an environment where it will not be exposed to excessive dust, dirt, moisture or any corrosive vapors. Cooling air louvers on the enclosure must not become clogged with snow, leaves, or any other foreign material. Inspect cooling air slots and openings on generator. These openings must be kept clean and unobstructed.

Check the cleanliness of the unit frequently and clean when dust, dirt, oil, moisture or other foreign substances are visible on its exterior/interior surface.

NOTE: DO NOT use direct spray from a garden hose to clean generator. Water can enter the engine and generator and cause problems.

Clean Debris

Use a damp cloth to wipe exterior surfaces clean.

Use a soft bristle brush to loosen caked on dirt or oil.

Use a vacuum cleaner to pick up loose dirt and debris.

17

Page 19
Image 19
Briggs & Stratton 40248 manuel dutilisation Maintenance Schedule, General Recommendations, Emissions Control, Clean Debris

40248 specifications

The Briggs & Stratton 40248 is a durable and efficient portable generator that has been designed to meet the demands of various outdoor activities, construction sites, and emergency backup power needs. With a reliable gasoline engine, the generator is capable of delivering solid performance in a wide range of applications.

One of the standout features of the Briggs & Stratton 40248 is its powerful 4500-watt surge and 3600-watt continuous output, providing ample power for essential appliances, tools, and equipment. This makes it an excellent choice for both recreational and emergency situations, ensuring that users have access to electricity when they need it most.

The generator is equipped with a reliable Ohv engine, known for its longevity and fuel efficiency. The 40248 includes a 3.5-gallon fuel tank, allowing for extended run times of up to 14 hours at a 25% load. This combination of powerful performance and efficient fuel consumption makes it an ideal option for long camping trips, outdoor events, or power outages.

In terms of portability, the Briggs & Stratton 40248 features an integrated handle and rugged wheels that make it easy to transport across various terrains. This enhanced mobility allows users to take the generator wherever it’s needed without hassle. Furthermore, its compact design ensures that it occupies minimal storage space.

Safety is a critical aspect of the Briggs & Stratton 40248, which includes features such as low oil shutdown to protect the engine from damage and overload protection to prevent equipment failure. These technologies ensure that your generator operates efficiently and safely, offering peace of mind to users.

The control panel is user-friendly, featuring multiple outlets including standard 120V outlets and a 12V automotive-style outlet, allowing for versatility in power options. This configuration makes it easy to connect various devices and enjoy uninterrupted power.

In summary, the Briggs & Stratton 40248 combines power, portability, and safety to deliver an outstanding generator for both recreational and emergency use. Its robust features, reliable engine, and user-oriented design make it a standout choice in the portable generator market, ensuring that users can meet their power needs confidently and conveniently. Whether powering tools on a job site or providing backup power during an outage, the 40248 excels in various environments.