MODELS EW5830SS • EW5836SS
OPERATION
Always turn the hood ON before cooking in order to establish an air flow in the kitchen. After turning off the range, let the hood run for a few minutes to clear the air.
Operate the hood as follows: | DELAY |
| |
OFF FAN | OFF LIGHT |
| FAN SPEED |
OFF | LED INDICATORS |
| |
Turns the fan OFF |
|
FAN
Turns the fan ON to the last selected speed, and activates a blue LED indicating the fan speed setting. Pressing the FAN button a second time will index the fan speed and LED indicator to the next highest setting. Pressing the FAN button when the fan is at the highest speed setting will index the fan and LED indicator to the lowest setting.
DELAY-OFF (10 Minute Delay-OFF)
Activates the 10 minute delay off feature when the fan is ON (any speed). When activated, the blue LED indicator above the selected speed setting will blink. The hood fan will automatically turn OFF after 10 minutes has elapsed. The
LIGHT (1-Pushbutton Switch, 3-Light Intensities)
Turns the lights ON to the lowest intensity. Pressing the LIGHT button a second time will index the light intensity to the next highest level. Pressing the LIGHT button when the lights are at the highest intensity will turn the lights off.
FILTER CHANGE INDICATION
After 30 hours of fan operation, the three blue LED indicators will blink simultaneously, indicating that it is time to clean the grease filters. To reset the filter clean timer, press and hold the OFF button for 3 seconds. The blinking LED indicators will turn off.
HEAT SENTRY SYSTEM
This range hood is equipped with a standard Heat Sentry system that monitors excessive temperature and automatically turns the fan speed on HIGH.
1)If the fan is ON, the Heat Sentry system will increase the fan setting to its highest speed when the temperature is elevated. The blue indicator for fan speed (3) will illuminate and blink at a high rate, indicating that the heat sentry function is activated. Once the temperature has reduced, the Heat Sentry system will change the fan speed to the original setting.
2)If the fan is OFF, the Heat Sentry system will automatically turn the fan on to its highest speed when the temperature is above normal. The blue indicator for fan speed (3) will illuminate and blink at a high rate, indicating that the heat sentry function is activated. After the temperature has lowered to normal, the fan will turn off.
Page 7
FUSES
The Range Hood Control Board contains a Main Fuse to protect the controls from power surges. New fuses can be purchased at a local electronic supply store. Use 5A, 120V, 5 mm diameter, 20 mm long,
To replace a fuse (by qualified person(s):
1.Disconnect power at service entrance.
2.Remove filters
3.Remove control cover
4.Remove and inspect fuse.
MAKE-UP AIR DAMPER
The hood is compatible with Broan
MAKE UP DAMPER CONNECTION | ||
| (switched low voltage) | |
| 20 GAUGE BELL WIRE FOR LOW | |
| VOLTAGE CONNECTION ON | |
| TOP OF HOOD |
|
24V |
|
|
TRANSFORMER | DRY CONTACT | |
(INCLUDED) |
| |
| TERMINAL | |
|
| |
GRD | HOOD | BUSHING |
|
| FOR LOW |
120 VAC |
| VOLTAGE |
60 HZ |
| CONNECTION |
Make the connection to the
REMOTE CONTROL
The hood is compatible with Broan Radio Frequency (RF) Remote Control Model BCR1 (optional). Purchase separately.
To link the BCR1 remote control with the hood, press and hold the LIGH T button for
The blue LED indicators will turn on and off in succession to indicate the hood is in RF linking mode. When in the linking mode, press any key on the RF remote. An audible beep will be heard at the hood, and the hood LED’s will stop blinking if a successful link is accomplished. If the remote control did not successfully link with the hood, the linking mode will be deactivated after 12 seconds, and the LED’s will stop the sequential blinking. Refer to the BCR1 instructions for additional information.