Broan QP130BL, QP130WW Install the Hood, NON-DUCTED Installation only, Ducted Installation only

Models: QP130BLC QP130WWC QP130SS QP130WW QP130BL QP136WW QP130SSC QP136SS QP136BL

1 20
Download 20 pages 1.96 Kb
Page 4
Image 4

MODELS QP130BL • QP130BLC • QP130SS • QP130SSC QP130WW • QP130WWC • QP136BL • QP136SS • QP136WW

CENTER

 

RETAINING SCREW

 

PULL

OUT

 

è

 

RECIRCULATION

SLIDE PLATE

OUTER

 

RETAINING SCREWS

 

7 NON-DUCTED INSTALLATION ONLY:

Remove Center Retaining Screw and loosen Outer Retaining Screws holding Recirculation Slide Plate in place. Pull out slide plate and replace and tighten retaining screws to hold slide plate in new (non-ducted) position.

8 NON-DUCTED INSTALLATION ONLY:

Purchase a set of (2) non-ducted filters from your local distributor or retailer. Attach the non-ducted filters to the aluminum mesh filters following instructions packed with the non-ducted filters.

FOR NON-DUCTED INSTALLATIONS - Skip to “INSTALL THE HOOD”.

7” ROUND

KNOCKOUT

PLATE (also

remove 3¼” x 10”

vertical plate)

 

3¼” X 10”

 

VERTICAL

 

KNOCKOUT

3¼” X 10”

PLATE

HORIZONTAL

 

KNOCKOUT

 

PLATE

 

9

DUCTED INSTALLATION ONLY:

 

Remove 3¼” x 10 vertical, 3¼” x 10” horizontal, or 7-inch

round knockout plate(s) as appropriate for your ducting method.

Page 4

TOP/BACK

3¼” X 10”

EDGE OF

DAMPER /

HOOD

DUCT

 

CONNECTOR

 

7” ROUND

 

DUCT

 

PLATE

10DUCTED INSTALLATION ONLY:

Attach 3¼” x 10” Damper/Duct Connector (if using 3¼” x 10” duct) or 7” Round Duct Plate (if using 7-inch round duct) over the knockout opening.

Note:

To accomodate off-center ductwork, the 3¼” x 10” damper/ duct connector can be installed up to ½” on either side

of the hood center and the 7” round duct plate can be installed up to ½” on either side of the hood center.

Trim the flange on the duct connector or duct plate if it interferes with the electrical cable clamp.

Install the 3¼” x 10” Damper/Duct Connector with the Damper Flap Pivot nearest the Top/Back Edge of Hood.

INSTALL THE HOOD

WARNING

To reduce the risk of electrical shock, switch power off at service panel. Lock or tag service panel to prevent power from being switched on accidentally.

ELECTRICAL

ELECTRICAL POWER

WIRING BOX

COVER

CABLE KNOCKOUT

11Remove Electrical Wiring Box Cover from inside

of hood and appropriate Electrical Power Cable Knockout from top or back of hood.

Page 4
Image 4
Broan QP130WW, QP130BLC, QP130SS NON-DUCTED Installation only, For NON-DUCTED Installations Skip to Install the Hood