MODELS QP330BL • QP330SS • QP330WW QP336BL • QP336SS • QP336WW QP342BL • QP342SS • QP342WW
HEAT SENTRY SYSTEM
This range hood is equipped with an advanced Heat Sentry system that monitors excessive temperature and automatically adjusts the fan to the appropriate setting.
1)If the fan is on, the Heat Sentry system will increase the fan setting when the temperature is elevated. If the temperature con- tinues to rise, the Heat Sentry system will continue to increase the fan setting until the temperature is stabilized or reduced. The flashing light above the fan button shows the Heat Sentry system fan setting. Once the temperature has reduced, the Heat Sentry system will change the fan to the original setting.
2)If the fan is off, the Heat Sentry system will automatically turn the fan on to its highest speed when the temperature is above normal. When the Heat Sentry system is on, the light above the high speed fan button will flash on and off. After the temperature has lowered to normal, the fan speed will be reduced until the temperature has stabilized, then the fan will turn off.
Page 4
MAKE-UP AIR DAMPER
The hood is compatible with Broan
Make the connection to the
BACK OF HOOD | |
| |
FOR |
|
RANGE | |
HOOD | DAMPER |
Note: Canadian version does not have this function.
FUSES |
|
| RANGE HOOD CONTROL BOARD |
MAIN | LIGHT |
FUSE | FUSE |
WIRES
120
VAC
24
VAC
DAMPER
MOTOR
The Range Hood Control Board contains a Main Fuse and a Light Fuse to protect the controls from power surges. If a fuse has opened (blown), the green fan setting or light setting indicators will not operate properly when the fan or light buttons are pressed, and
REMOTE CONTROL
The hood is compatible with Broan RF Remote Control Model BCR1 (optional). Purchase separately.
PREPARE HOOD LOCATION
ROOF CAP | 3¼" X 10" or |
| 7" ROUND DUCT |
| (For vertical |
| discharge) |
the fan and lights will not turn on.
New fuses can be purchased at your local electronic supply store. Use 8A, 120V, 5 mm diameter, 20 mm long,
To replace a fuse:
1.Disconnect power at service entrance.
2.Remove filters and bottom pan.
3.Remove and inspect fuse. If it is not open (blown), additional diagnostics are needed.
SOFFIT |
CABINET |
HOOD |
24" - 30" ABOVE |
COOKING SURFACE |
HOUSE WIRING (Top or Back of hood)
WALL CAP
3¼" X 10" DUCT
(For horizontal discharge)
1 | Determine whether hood will discharge vertically (3¼” |
| x 10” or 7” Round), or horizontally (3¼” x 10” only). For |
| vertical or horizontal discharge, run ductwork between |
| the hood location and a roof cap or wall cap. For best |
| results, use a minimum number of transitions and elbows. |