MODELS QP330BL • QP330SS • QP330WW QP336BL • QP336SS • QP336WW QP342BL • QP342SS • QP342WW

NON-DUCT

DIVERTER

8 NON-DUCTED INSTALLATION ONLY:

From parts bag: Attach Non-Duct Diverter to Air Box with 2 Screws and 2 Washers.

SCREWS

NON-DUCT

PLATE

NON-DUCT

PLATE

SLOT

NON-DUCT

PLENUM

9 NON-DUCTED INSTALLATION ONLY:

Remove 2 Screws holding Non-Duct Plate to Non-Duct Plenum and remove plate.

SCREWS

NON-DUCT

PLATE

10NON-DUCTED INSTALLATION ONLY:

Insert short end of Non-Duct Plate into Non-Duct Plenum Slot. Attach with 2 Screws removed in Step 9.

Page 6

11NON-DUCTED INSTALLATION ONLY:

Purchase a set of (2) non-ducted filters for 30” wide hoods (Model BPPF30) & 36” wide hoods (Model BPPF36) or a set of (3) non-ducted filters for 42” wide hoods (Model BPPF42) from your local distributor or retailer. Attach the non-ducted filters to the aluminum mesh filters following instructions packed with the non-ducted filters.

FOR NON-DUCTED INSTALLATIONS - Skip to “INSTALL THE HOOD”.

7” ROUND

KNOCKOUT

PLATE (also

remove 3¼” x 10”

vertical plate)

 

3¼” X 10”

 

VERTICAL

 

KNOCKOUT

3¼” X 10”

PLATE

HORIZONTAL

 

KNOCKOUT

 

PLATE

 

12DUCTED INSTALLATION ONLY:

Remove 3¼” x 10 vertical, 3¼” x 10” horizontal, or 7-inch round knockout plate(s) as appropriate for your ducting

method.

 

 

3¼” X 10”

TOP/BACK

DAMPER / DUCT CONNECTOR

 

EDGE OF

DAMPER

HOOD

 

FLAP

 

PIVOT

 

7” ROUND

 

DUCT

 

PLATE

13DUCTED INSTALLATION ONLY:

Attach 3¼” x 10” Damper/Duct Connector (if using 3¼” x 10” duct) or 7” Round Duct Plate (if using 7-inch round duct) over the knockout opening.

Notes:

To accomodate off-center ductwork, the 3¼” x 10” damper/ duct connector can be installed up to ½” on either side

of the hood center and the 7” round duct plate can be installed up to ½” on either side of the hood center.

Install the 3¼” x 10” Damper/Duct Connector with the

Damper Flap Pivot nearest the Top/Back Edge of Hood.

Page 6
Image 6
Broan QP330BL, QP342SS, QP336WW, QP330WW NON-DUCTED Installation only, For NON-DUCTED Installations Skip to Install the Hood