TROUBLESHOOTING

Although the manufacturer has attempted to ensure that your grill will operate properly and satisfactorily, sometimes problems do arise. The following troubleshooting guide lists several possible problems and their probable cause and solution.

Problem

Cause

Solution

Burner will not light.

Gas injector not inserted in venturi tube.

Realign/engage gas injector with the

 

 

venturi tube.

 

Clogged gas injector.

Remove gas injector from gas control as-

 

 

sembly and clean.

 

Obstruction in gas line.

For propane models, ensure gas valve on

 

 

cylinder is OFF. Remove flexible hose and

 

 

blow out any debris.

 

Spider webs in venturi tubes.

Clean venturi tubes. See Maintenance

 

 

Section on page 21

 

Misalignment of electrode.

Position electrode properly.

 

Out of gas.

Refill LP gas cylinder. If natural model,

 

 

turn on gas at source.

 

Dead battery.

Replace with “AA” Alkaline battery.

Inadequate grill temperature.

Poor combustion.

Adjust air shutter.

 

Misalignment of venturi tube and gas

Realign/engage gas injector with the

 

injector.

venturi tube.

 

Inadequate gas pressure.

Contact gas supplier for assistance.

 

Incorrect orifice/valve setting.

Refer to gas conversion instructions in this

 

 

manual.

Flames blow out

Cold grill.

Preheat grill at least 5 minutes on HI with

 

 

the grill lid closed.

 

Misalignment of burner tube and gas

Realign/engage gas injector with the

 

injector.

burner tube.

 

Poor combustion.

Adjust air shutter.

 

Extreme wind.

Turn or shield grill.

Yellow flames.

Air shutter improperly set.

Open air shutter.

 

Spider webs in venturi tubes.

Clean venturi tubes. See Maintenance

 

 

Section.

 

Seasoning salts on burner.

Clean by washing burner with mild deter-

 

 

gent.

 

Oil film on burner.

Allow burner to operate on HI for 10 to 15

 

 

minutes.

Page 22

SBB00104-3-0309

Page 22
Image 22