Changing Needles and Light Bulb

Note

Please make sure power is off before carrying out the following operations. There is a chance of injury if the machine accidentally starts running during this operation.

Changing the Feed Pin

1Set the feed dogs to "velvet"

position. (see Page 5)

2Remove needle, presser

foot and needle plate.

Note

Please make sure power is off before carrying out the following operation. The glass plate over the light bulb will be hot immediately after using the machine, so you should wait until the machine has had a chance to cool down before changing bulbs.

CONTENTS

Accessories

Changing the Needle

1Turn the sewing machine off. Raise needle to highest position using hand wheel, and lower presser foot.

2Loosen screw with screw- driver, and remove needle.

3Insert new needle, and tighten screw. Make sure needle is screwed in tightly.

Check needles on a flat surface to make sure they're not bent.

Screwdriver

The needle should lay parallel to a surface.

flat surface

Lay needle on a flat surface

(such as the needle plate or a plate

of glass).

3Lower presser foot and turn hand wheel until feed

pin is in its highest position.

4Insert small screwdriver (included) as shown in diagram.

5While holding spring with fingertip, lower the feed pin changer onto the needle to pick it up.

6Attach new feed pin to feed pin changer, lower and attach while holding spring with fingertip.

7Remove screwdriver.

8Re-attach needle plate, needle and presser foot.

Changing Light Bulbs

1Turn off power.

2 Remove screws from Screwdriver head.

3Remove head.

4Unscrew bulb and remove.

5 Screw in new bulb. Rated 120V 15W

6 Re-attach head and tighten screw.

Light

Parts

Names

 

of

Begin

Before You

Light Bulb

Needles and

Changing

 

Threading

 

Needle Chart

Samples and

Stitch

Presser Feet

Changing

Sewing

Basic

Machine

Your

Caring for

Note

HLX5 needles should be uses; however, Schmetz 130/705H may also be used under normal

610 circumstances.

Bulb

Shooting

Trouble

Page 10
Image 10
Brother PQ1300 Changing Needles and Light Bulb, Changing the Feed Pin, Remove screwdriver, Unscrew bulb and remove