Bryant 310JAV, 310AAV warranty GAS Rate CU FT/HR, Check Safety Controls

Models: 310JAV 310AAV

1 45
Download 45 pages 34.04 Kb
Page 30
Image 30

Table 8–GAS RATE (CU FT/HR)

SECONDS

SIZE OF TEST DIAL

SECONDS

SIZE OF TEST DIAL

FOR 1

1

2

5

FOR 1

1

2

5

REVOLUTION

Cu Ft

Cu Ft

Cu Ft

REVOLUTION

Cu Ft

Cu Ft

Cu Ft

 

 

 

 

 

 

 

 

10

360

720

1800

50

72

144

360

11

327

655

1636

51

71

141

355

 

 

 

 

 

 

 

 

12

300

600

1500

52

69

138

346

 

 

 

 

 

 

 

 

13

277

555

1385

53

68

136

340

14

257

514

1286

54

67

133

333

 

 

 

 

 

 

 

 

15

240

480

1200

55

65

131

327

 

 

 

 

 

 

 

 

16

225

450

1125

56

64

129

321

17

212

424

1059

57

63

126

316

18

200

400

1000

58

62

124

310

 

 

 

 

 

 

 

 

19

189

379

947

59

61

122

305

 

 

 

 

 

 

 

 

20

180

360

900

60

60

120

300

21

171

343

857

62

58

116

290

 

 

 

 

 

 

 

 

22

164

327

818

64

56

112

281

 

 

 

 

 

 

 

 

23

157

313

783

66

54

109

273

24

150

300

750

68

53

106

265

 

 

 

 

 

 

 

 

25

144

288

720

70

51

103

257

 

 

 

 

 

 

 

 

26

138

277

692

72

50

100

250

27

133

267

667

74

48

97

243

 

 

 

 

 

 

 

 

28

129

257

643

76

47

95

237

 

 

 

 

 

 

 

 

29

124

248

621

78

46

92

231

 

 

 

 

 

 

 

 

30

120

240

600

80

45

90

225

31

116

232

581

82

44

88

220

 

 

 

 

 

 

 

 

32

113

225

563

84

43

86

214

 

 

 

 

 

 

 

 

33

109

218

545

86

42

84

209

34

106

212

529

88

41

82

205

 

 

 

 

 

 

 

 

35

103

206

514

90

40

80

200

 

 

 

 

 

 

 

 

36

100

200

500

92

39

78

196

37

97

195

486

94

38

76

192

 

 

 

 

 

 

 

 

38

95

189

474

96

38

75

188

 

 

 

 

 

 

 

 

39

92

185

462

98

37

74

184

 

 

 

 

 

 

 

 

40

90

180

450

100

36

72

180

41

88

176

439

102

35

71

178

 

 

 

 

 

 

 

 

42

86

172

429

104

35

69

173

 

 

 

 

 

 

 

 

43

84

167

419

106

34

68

170

44

82

164

409

108

33

67

167

 

 

 

 

 

 

 

 

45

80

160

400

110

33

65

164

 

 

 

 

 

 

 

 

46

78

157

391

112

32

64

161

47

76

153

383

116

31

62

155

 

 

 

 

 

 

 

 

48

75

150

375

120

30

60

150

 

 

 

 

 

 

 

 

49

73

147

367

 

 

 

 

 

 

 

 

 

 

 

 

To change the blower off delay setting, move the jumper from one set of pins on the control to the pins used for the selected blower off delay. Factory off delay setting is 120 sec.

Step 4—Check Safety Controls

The flame sensor, gas valve, and pressure switch were all checked in the Start-up procedure section as part of normal operation.

1.Check Main Limit Switches

This control shuts off combustion control system and ener- gizes air-circulating blower motor, if furnace overheats. By using this method to check limit control, it can be established that limit is functioning properly and will operate if there is a restricted duct system or motor failure. If limit control does not function during this test, cause must be determined and corrected.

a.Run furnace for at least 5 minutes.

b.Gradually block off return air with a piece of cardboard or sheet metal until the limit trips.

c.Unblock return air to permit normal circulation.

THERMOSTAT SUBBASE TERMINALS WITH THERMOSTAT REMOVED (ANITICIPATOR, CLOCK, ETC.,

MUST BE OUT OF CIRCUIT.)

HOOK-AROUND

AMMETER

R Y W G

10 TURNS

FROM UNIT 24-V

CONTROL TERMINALS

EXAMPLE:

5.0 AMPS ON AMMETER

=

0.5 AMPS FOR THERMOSTAT

10 TURNS AROUND JAWS

ANTICIPATOR SETTING

 

 

 

 

 

A96316

Fig. 42—Amp Draw Check With Ammeter

d.Burners will re-light when furnace cools down.

2.Check draft safeguard switch.

The purpose of this control is to permit the safe shutdown of the furnace during certain blocked vent conditions.

a.Verify vent pipe is cool to the touch.

b.Disconnect power to furnace and remove vent connector from furnace vent elbow.

c.Restore power to furnace and set room thermostat above room temperature.

d.After normal start-up, allow furnace to operate for 2 minutes, then block vent elbow in furnace 80 percent of vent area with a piece of flat sheet metal.

e.Furnace should cycle off within 2 minutes.

f.Remove blockage and reconnect vent pipe to furnace vent elbow.

g.Switch will auto-reset when it cools.

h.If control board locks out furnace, cycle 115 vac power to reset control.

3.Check Pressure Switch(es)

This control proves operation of the draft inducer blower.

a.Turn off 115-v power to furnace.

b.Disconnect inducer motor lead wires from wire harness.

c.Turn on 115-v power to furnace.

d.Set thermostat to call for heatand wait 1 minute. When pressure switch is functioning properly, hot surface igniter should NOT glow and control diagnostic light flashes a status code 32. If hot surface igniter glows when inducer motor is disconnected, shut down furnace immediately.

e.Determine reason pressure switch did not function properly and correct condition.

f.Turn off 115-v power to furnace.

g.Reconnect inducer motor wires, replace outer door, and turn on 115-v power.

29

Page 30
Image 30
Bryant 310JAV, 310AAV warranty GAS Rate CU FT/HR, Check Safety Controls