| Read This Before Installing Thermostat | 6 |
| |
|
|
| |||
|
| IMPORTANT | SYSTEM COMPATIBILITY |
|
|
|
| Read the entire installation section of this Owner’s Manual | Your Thermostat is designed to operate these |
| |
|
| 1thoroughly before you begin to install or operate your |
| ||
|
| Hunter Thermostat. | ■ |
| |
|
| Remove the Mylar label from the LCD display window. |
| ||
|
| ■ |
| ||
|
|
|
| ||
|
| INSTALLATION | ■ 2, 3, or 4 wire gas, oil, and electric furnaces and air condition- |
| |
|
| ing systems |
| ||
|
| All installation is normally performed at your |
| ||
|
|
|
|
| |
|
| 2thermostat. | This thermostat will not control 120/240 Volt systems or |
| |
|
| ARMCHAIR PROGRAMMING | millivolt systems. |
| |
|
| COMPRESSOR PROTECTION |
| ||
|
| You can program your thermostat before installation by in- |
| ||
|
| 3serting the batteries and following the instructions starting | The thermostat provides a 3.5 minute delay after shutting off |
| |
|
| on page 16. This can be done while you relax in your favorite | 5the heating or cooling system before it can be restarted. |
| |
|
| chair and is a very good way to familiarize yourself with all the | This feature will prevent damage to your compressor caused |
| |
|
| functions of your Hunter Thermostat. | by rapid cycling. |
| |
|
|
|
|
|
|
|
|
|
|
|
|
7
| TEMPERATURE RANGE | BATTERY WARNING |
|
|
| ||
| Your thermostat can be programmed between 45°F and 95°F | Fresh alkaline batteries will provide over one year of memory |
|
| 6(7°C and 35°C). However, it will display room temperatures | 9backup and clock operation. However, when the batteries |
|
| from 15°F to 99°F | become drained, a low battery warning will appear on the dis- |
|
| temperature is higher than 99°F (37°C), and “LO” will be dis- | play. When this message occurs, install 2 new AAA batteries. You |
|
| played if the temperature is lower than 15°F | have approximately 30 seconds when changing the batteries to |
|
| AUTO RECOVERY | keep thermostat’s clock and program settings. |
|
| NOTE: The default system selection at |
| |
| Your thermostat is set from the factory to gradually recover |
| |
| Batteries are recommended to prevent an undesired sys- |
| |
| 7the room temperature from an energy saving program to |
| |
| tem change due to a power outage. |
| |
| your comfort program. Therefore, the thermostat may turn your |
|
|
| system on several minutes prior to your programmed time. This |
|
|
| operation is normal, but can be turned off. Refer to the Options |
|
|
| Menu information on pages 16. |
|
|
| OPERATION |
|
|
| This system operates on your system’s 24 Volt power supply. |
|
|
| 8The supply is monitored by the thermostat, and it will stop |
|
|
| functioning if AC power is lost. (When using backup batteries, |
|
|
| “No AC Pwr” will be displayed.) All system controls will remain |
|
|
| off until power is restored. |
|
|
| NOTE: The INDIGLO® |
|
|
| AC power is lost. |
|
|
|
|
|
|
|
|
|
|