PROGRAMMING

16

Option Menu

 

 

Your thermostat has many settings that can be adjusted to fit your system and preferences.

 

option

■ Press to enter the Option Menu and to change to the next option selection.

 

ret-clear■ Press at any time to return to normal mode.

Fahrenheit or Celsius (F°/C°) selection

option

1

or

to change the thermostat display between

Temp

 

 

 

Fahrenheit and Celsius.

 

 

12 Hr or 24 Hr. Clock selection

 

 

 

option

2

or

to change the time format display between

Clock

 

12 hour (AM / PM) and 24 hour (military).

17

Stage 1 SPAN selection

 

Span Stg1

 

 

option 3

or

to change the SPAN setting to 1, 2, or 3. The

factory setting is 2. Setting 1 will cause shorter cycle times. Setting 3 will cause longer cycle times.

Auto Recovery selection

 

 

option 4

or

to enable “YES” or disable “NO” the Auto

 

 

Recovery Mode. The factory setting is “YES.”

system ■ To change between Heat or Cool recovery modes.

Recovery

System

NOTE: Auto Recovery is one of the ENERGY STAR® features of this thermostat. Refer to the Auto Recovery section on pages 45-46 for more information.

LCD Contrast adjustment

 

 

 

or

to change the LCD contrast between 0 and 9.

LCD

option 5

Lower numbers lighten the display. Higher numbers darken the display.

 

 

The factory setting is 5.