DETAILED COOLING CAPACITIES* Continued

EVAP

 

 

 

 

 

CONDENSER ENTERING AIR TEMPERATURES °F

 

 

 

 

AIR

75

 

85

 

95

 

105

 

 

115

 

125

 

 

 

Capacity

Total

Capacity

Total

Capacity

Total

Capacity

Total

 

Capacity

Total

Capacity

Total

 

 

MBtuh†

MBtuh†

MBtuh†

MBtuh†

 

MBtuh†

MBtuh†

 

 

Sys

Sys

Sys

Sys

 

Sys

Sys

CFM

EWB

Total

Sens‡

Kw**

Total

Sens‡

Kw**

Total

Sens‡

Kw**

Total

Sens‡

Kw**

Total Sens‡

Kw**Total Sens‡

Kw**

533AN060-A Outdoor Section With CK5AA060 Indoor Section

 

 

72

 

67.5

32.8

 

4.50

 

64.6

 

31.8

 

4.99

61.6

 

30.7

5.54

 

58.3

 

29.5

6.14

 

54.8

 

28.3

 

6.81

 

50.8

26.9

 

7.57

 

 

 

67

 

62.8

41.9

 

4.44

 

59.7

 

40.6

 

4.91

56.7

 

39.4

5.45

 

53.3

 

38.0

6.06

 

49.9

 

36.7

 

6.71

 

44.2

34.5

 

7.42

 

1600

 

63††

 

55.5

39.5

 

4.32

 

51.6

 

37.8

 

4.77

47.6

 

36.0

5.27

 

45.3

 

35.1

5.88

 

42.7

 

33.9

 

6.55

 

39.1

32.5

 

7.28

 

 

 

62

 

54.2

48.8

 

4.30

 

50.5

 

47.1

 

4.75

46.7

 

45.2

5.26

 

44.5

 

44.1

5.86

 

42.7

 

42.7

 

6.55

 

40.2

40.2

 

7.30

 

 

 

57

 

50.9

50.9

 

4.25

 

47.8

 

47.8

 

4.70

46.1

 

46.1

5.25

 

44.2

 

44.2

5.85

 

42.4

 

42.4

 

6.54

 

40.4

40.4

 

7.30

 

 

 

72

 

68.2

33.7

 

4.58

 

65.4

 

32.8

 

5.08

62.4

 

31.7

5.63

 

59.0

 

30.6

6.24

 

55.4

 

29.4

 

6.91

 

51.3

28.1

 

7.66

 

 

 

67

 

63.8

43.9

 

4.52

 

60.8

 

42.8

 

5.01

57.4

 

41.4

5.54

 

54.1

 

40.1

6.15

 

50.5

 

38.8

 

6.82

 

44.8

36.6

 

7.52

 

1800

 

63††

 

56.6

41.6

 

4.41

 

52.6

 

39.9

 

4.87

50.4

 

39.0

5.41

 

48.0

 

38.0

6.01

 

45.4

 

36.8

 

6.69

 

39.9

34.6

 

7.38

 

 

 

62

 

55.5

51.9

 

4.40

 

51.8

 

50.1

 

4.85

49.7

 

49.1

5.39

 

47.7

 

47.7

6.01

 

45.8

 

45.8

 

6.70

 

41.7

41.7

 

7.43

 

 

 

57

 

52.9

52.9

 

4.36

 

51.2

 

51.2

 

4.84

49.4

 

49.4

5.38

 

47.4

 

47.4

6.00

 

45.6

 

45.6

 

6.70

 

41.9

41.9

 

7.43

 

 

 

72

 

68.8

34.6

 

4.67

 

66.0

 

33.7

 

5.16

62.9

 

32.7

5.72

 

59.5

 

31.7

6.33

 

55.8

 

30.5

 

7.00

 

51.7

29.2

 

7.75

 

 

 

67

 

64.4

45.6

 

4.60

 

61.5

 

44.6

 

5.09

58.0

 

43.2

5.62

 

54.7

 

42.1

6.23

 

51.1

 

40.9

 

6.91

 

45.8

38.9

 

7.62

 

2000

 

63††

 

57.6

43.6

 

4.51

 

53.9

 

42.1

 

4.96

52.9

 

41.7

5.53

 

50.5

 

40.7

6.14

 

45.6

 

38.7

 

6.78

 

40.5

36.6

 

7.47

 

 

 

62

 

56.8

54.9

 

4.49

 

54.7

 

53.9

 

4.97

52.5

 

52.5

5.52

 

50.5

 

50.5

6.15

 

47.8

 

47.8

 

6.82

 

43.0

43.0

 

7.55

 

 

 

57

 

56.1

56.1

 

4.48

 

54.1

 

54.1

 

4.97

52.3

 

52.3

5.52

 

50.3

 

50.3

6.14

 

47.8

 

47.8

 

6.82

 

43.1

43.1

 

7.55

 

 

 

 

 

 

 

 

 

 

Multipliers for Determining the Performance With Other Indoor Sections

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Indoor

 

 

 

 

 

 

 

 

Cooling

 

 

 

 

 

Indoor

 

 

 

 

 

 

 

 

Cooling

 

 

 

 

 

 

Section

 

Size

 

 

Capacity

 

 

 

Power

 

 

 

Section

 

Size

 

 

Capacity

 

 

 

Power

 

 

CC5A/CD5AA

060

 

 

 

0.95

 

 

 

0.98

 

 

 

FX4ANB

 

060

 

 

 

0.97

 

 

 

1.01

 

 

 

CC5A/CD5AW

060

 

 

 

1.00

 

 

 

1.00

 

 

 

 

COILS + 333(B,J)AV060100 VARIABLE SPEED FURNACE

 

 

 

 

CE3AA

 

060

 

 

 

0.98

 

 

 

1.00

 

 

CC5A/CD5AA

060

 

 

 

0.97

 

 

 

0.96

 

 

 

 

 

CK3BA

 

060

 

 

 

0.98

 

 

 

1.00

 

 

CC5A/CD5AW

060

 

 

 

1.00

 

 

 

0.96

 

 

 

CK5A/CK5BA

060

 

 

 

1.00

 

 

 

1.00

 

 

 

 

CK3BA

 

060

 

 

 

1.00

 

 

 

0.96

 

 

 

CK5A/CK5BT

060

 

 

 

0.98

 

 

 

1.00

 

 

CK5A/CK5BA

060

 

 

 

1.00

 

 

 

0.96

 

 

 

CK5A/CK5BX

060

 

 

 

1.00

 

 

 

1.00

 

 

CK5A/CK5BX

060

 

 

 

1.00

 

 

 

0.96

 

 

 

F(A,B)4AN(F,B,C)

060

 

 

 

0.98

 

 

 

1.04

 

 

 

 

COILS + 333(B,J)AV060120 VARIABLE SPEED FURNACE

 

 

 

FB4ANB

 

070

 

 

 

1.00

 

 

 

1.02

 

 

CC5A/CD5AA

060

 

 

 

0.97

 

 

 

0.97

 

 

 

FC4BN(F,B)

060

 

 

 

0.98

 

 

 

1.03

 

 

CC5A/CD5AW

060

 

 

 

1.00

 

 

 

0.96

 

 

 

 

FC4BNB

 

070

 

 

 

1.00

 

 

 

1.01

 

 

 

 

CK3BA

 

060

 

 

 

1.00

 

 

 

0.97

 

 

 

 

FG3AAA

 

060

 

 

 

0.97

 

 

 

1.00

 

 

CK5A/CK5BA

060

 

 

 

1.00

 

 

 

0.97

 

 

 

 

FK4CNB

 

006

 

 

 

1.00

 

 

 

0.95

 

 

CK5A/CK5BX

060

 

 

 

1.00

 

 

 

0.97

 

 

 

 

FV4ANB

 

006

 

 

 

1.00

 

 

 

0.95

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

* Detailed cooling capacities are based on indoor and outdoor unit at the same elevation per ARI standard 210/240-94. If additional tubing length and/or indoor unit is located above outdoor unit, a slight variation in capacity may occur.

† Total and sensible capacities are net capacities. Blower motor heat has been subtracted.

Sensible capacities shown are based on 80°F (27°C) entering air at the indoor coil. For sensible capacities at other than 80°F (27°C), deduct 835 Btuh (245 kw) per 1000 CFM (480 L/S) of indoor coil air for each degree below 80°F (27°C), or add 835 Btuh (245 kw) per 1000 CFM (480 L/S) of indoor coil air per degree above 80°F (27°C). When the required data falls between the published data, interpolation may be performed.

** Unit kw is outdoor unit kilowatts only.

††At TVA rating indoor condition (75°F edb/63°F ewb). All other indoor air temperatures are at 80°F edb. ‡‡ Data are with FC4 and FK4 R-22 TXV replaced with Puron® TXV.

—19—