Bryant 548J manual Heating Capacity, Tons

Models: 548J

1 76
Download 76 pages 14.11 Kb
Page 34
Image 34
Table 18 – HEATING CAPACITY

548J

Table 18 – HEATING CAPACITY

 

 

 

 

 

 

 

7.5 TONS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

548J*08

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RETURN

 

CFM

 

TEMPERATURE AIR ENTERING OUTDOOR COIL (°F db at 70% rh)

 

AIR

 

 

 

 

 

 

 

 

 

 

 

(°F db)

(STANDARD AIR)

---10

0

10

 

17

30

40

47

50

60

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2250

 

Capacity

 

 

46.9

 

53.5

66.3

77.2

86.2

89.4

103.3

 

 

Int. Cap.

 

 

43.1

 

48.7

58.1

77.2

86.2

89.4

103.3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

55

3000

 

Capacity

 

 

 

 

 

68.5

80.2

89.8

93.1

106.7

 

Int. Cap.

 

 

 

 

 

60.0

80.2

89.8

93.1

106.7

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3750

 

Capacity

 

 

 

 

58.9

72.5

84.6

94.5

97.6

110.6

 

 

Int. Cap.

 

 

 

 

53.7

63.5

84.6

94.5

97.6

110.6

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2250

 

Capacity

25.9

34.6

43.6

 

50.2

62.7

73.0

81.4

84.5

98.0

 

 

Int. Cap.

23.9

31.8

40.0

 

45.7

55.0

73.0

81.4

84.5

98.0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

70

3000

 

Capacity

27.4

36.2

45.5

 

52.2

65.1

75.9

85.0

88.2

102.1

 

Int. Cap.

25.3

33.4

41.8

 

47.6

57.0

75.9

85.0

88.2

102.1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3750

 

Capacity

31.0

40.0

49.3

 

56.1

69.1

80.4

89.8

93.2

106.5

 

 

Int. Cap.

28.6

36.8

45.3

 

51.1

60.6

80.4

89.8

93.2

106.5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2250

 

Capacity

22.5

31.5

40.7

 

47.3

60.1

70.3

78.2

81.2

94.3

 

 

Int. Cap.

20.8

29.0

37.3

 

43.1

52.6

70.3

78.2

81.2

94.3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

80

3000

 

Capacity

24.1

33.3

42.7

 

49.5

62.5

73.1

81.6

84.7

98.6

 

Int. Cap.

22.3

30.6

39.2

 

45.2

54.8

73.1

81.6

84.7

98.6

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3750

 

Capacity

27.8

37.1

46.6

 

53.5

66.7

77.5

86.4

89.7

103.4

 

 

Int. Cap.

25.7

34.1

42.8

 

48.8

58.4

77.5

86.4

89.7

103.4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Table 19 – HEATING CAPACITY

 

 

 

 

 

 

 

8.5 TONS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

548J*09

 

 

 

 

 

 

 

RETURN

 

 

CFM

 

TEMPERATURE AIR ENTERING OUTDOOR COIL (°F db at 70% rh)

 

 

AIR

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(STANDARD AIR)

 

 

 

 

 

 

 

 

 

 

 

(°F db)

 

---10

0

10

 

17

30

40

47

50

60

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2550

 

Capacity

33.1

42.7

52.7

 

60.0

75.6

87.4

97.5

100.6

113.8

 

 

 

 

 

Int. Cap.

30.7

39.3

48.3

 

54.7

66.2

87.4

97.5

100.6

113.8

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

55

 

3400

 

Capacity

34.4

44.0

54.2

 

61.8

77.5

89.9

100.2

103.1

115.7

 

 

 

Int. Cap.

31.8

40.5

49.8

 

56.4

67.9

89.9

100.2

103.1

115.7

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4250

 

Capacity

38.0

47.7

58.0

 

65.8

81.5

94.2

103.9

106.6

118.2

 

 

 

 

 

Int. Cap.

35.2

43.9

53.2

 

60.0

71.4

94.2

103.9

106.6

118.2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2550

 

Capacity

29.0

38.6

48.6

 

55.9

70.7

83.5

93.1

96.2

109.5

 

 

 

 

 

Int. Cap.

26.8

35.5

44.6

 

51.0

61.9

83.5

93.1

96.2

109.5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

70

 

3400

 

Capacity

30.3

40.2

50.4

 

58.0

73.5

86.1

96.5

99.2

111.9

 

 

 

Int. Cap.

28.0

37.0

46.3

 

52.9

64.4

86.1

96.5

99.2

111.9

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4250

 

Capacity

34.0

44.0

54.4

 

62.1

77.8

90.5

100.5

103.3

115.2

 

 

 

 

 

Int. Cap.

31.5

40.5

50.0

 

56.6

68.2

90.5

100.5

103.3

115.2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2550

 

Capacity

25.3

35.0

45.2

 

52.6

67.1

80.0

90.0

93.2

106.5

 

 

 

 

 

Int. Cap.

23.4

32.2

41.5

 

48.0

58.8

80.0

90.0

93.2

106.5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

80

 

3400

 

Capacity

26.6

36.7

47.2

 

54.8

69.8

83.0

93.1

96.2

109.2

 

 

 

Int. Cap.

24.6

33.8

43.3

 

50.0

61.2

83.0

93.1

96.2

109.2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4250

 

Capacity

30.4

40.6

51.2

 

59.0

74.4

87.7

97.7

100.7

112.8

 

 

 

 

 

Int. Cap.

28.1

37.4

47.0

 

53.8

65.1

87.7

97.7

100.7

112.8

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

--- Indicates operation not permissible

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LEGEND

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Capacity ---

Instantaneous Capacity (1000 Btuh) includes indoor fan motor heat @ARI static conditions

 

 

 

Int. Cap. --- Integrated Capacity is Instantaneous Capacity minus the effects of frost on the outdoor coil and the heat required to defrost

rh

---

Relative Humidity

db

---

Dry Bulb

34

Page 34
Image 34