ACCESSORY USAGE GUIDELINE

 

REQUIRED FOR

REQUIRED FOR

REQUIRED FOR

 

LOW-AMBIENT

LONG-LINE

SEA COAST

 

APPLICATIONS

APPLICATIONS*

APPLICATIONS

ACCESSORY

(Below 55°F)

(Over 50 Ft)

(Within 2 Miles)

 

 

 

 

Crankcase Heater

Yes

Yes

No

 

 

 

 

Evaporator Freeze Thermostat

Yes

No

No

 

 

 

 

Winter Start Control

Yes†

No

No

 

 

 

 

Accumulator

No

No

No

 

 

 

 

Compressor Start Assist

Yes

Yes

No

Capacitor and Relay

 

 

 

 

 

 

 

MotorMaster® Control

 

 

 

or

Yes

No

No

Low-Ambient Pressure Switch

 

 

 

 

 

 

 

Wind Baffle

See Low-Ambient Instructions

No

No

 

 

 

 

Coastal Filter

No

No

Yes

 

 

 

 

Support Feet

Recommended

No

Recommended

 

 

 

 

Liquid-Line Solenoid Valve

 

See Long-Line

 

or

No

Application

No

Hard Shutoff TXV

 

Guideline

 

 

 

 

 

Ball Bearing Fan Motor

Yes‡

No

No

 

 

 

 

*For tubing line sets greater than 50 ft and/or 20 ft vertical differential, refer to Application Guideline and Service Manual—Air Conditioning and Heat Pumps Using Puron®

Refrigerant.

Only when low-pressure switch is used.

Required for low-ambient controller (full modulation feature) and MotorMaster® Control only.

ACCESSORY DESCRIPTION AND USAGE (Listed Alphabetically)

1.Ball Bearing Fan Motor

A fan motor with ball bearings which permits speed reduction while maintaining bearing lubrication.

SUGGESTED USE: Required on all units where Low-Ambient Controller (full modulation feature) or MotorMaster® Control has been added.

2.Coastal Filter

A mesh screen inserted under the top cover and inside base pan to protect the condenser coil from corrosive atmosphere without restricting airflow.

SUGGESTED USE: In geographic areas where salt damage could occur.

In areas with high pollution levels.

3.Compressor Start Assist—Capacitor/Relay Type

Start capacitor and start relay which gives a hard” boost to compressor motor at each start-up.

SUGGESTED USE: Installations where interconnecting tube length exceeds 50 ft.

Installations where outdoor design temperature exceeds 105°F (40.6°C).

Installations where low voltage or brown-out conditions may occur.

4.Compressor Start Assist—PTC Type

Solid-state electrical device which gives a soft” boost to compressor motor at each start-up.

SUGGESTED USE: Installations with marginal power supply.

5.Crankcase Heater

An electric resistance heater which mounts to the base of the compressor to keep the lubricant warm during off cycles. Improves compressor lubrication

on restart and minimizes chance of refrigerant slugging. May or may not include a thermostat control. SUGGESTED USE: When interconnecting tube length exceeds 50 ft.

When unit will be operated below 55°F (12.8°C) outdoor air temperature. Use with Low-Ambient Controller. All commercial installations.

6.Cycle Protector

Solid state timing device which prevents compressor rapid recycling. Control provides an approximate 5-minute delay after power to the compressor has been interrupted for any reason, including normal room thermostat cycling.

SUGGESTED USE: Installations in areas where power interruptions are frequent.

Where user is likely to play” with the room thermostat.

All commercial installations.

Installations where interconnecting tube length exceeds 50 ft.

High-rise applications.

7.Evaporator Freeze Thermostat

An SPST temperature actuated switch which stops unit operation when evaporator reaches freeze-up conditions.

SUGGESTED USE: All units where Winter Start Control has been added.

8.Filter Drier (Suction Line)

A device for removing contaminants from refrigerant circulating in an air conditioner: one direction flow.

SUGGESTED USE: All split-system air conditioners.

9.Liquid-Line Solenoid Valve (LSV)

An electrically operated shutoff valve to be installed at the outdoor or indoor unit (depending on tubing configuration) and which stops and starts refrigerant liquid flow in response to compressor operation. Maintains a column of refrigerant liquid ready for action at next compressor operation cycle.

SUGGESTED USE: For improved system performance in air conditioners for certain combinations of indoor and outdoor units. Refer to ARI Unitary Directory. In certain long-line applications. Refer to Residential Split System Long-Line Application Guideline and Service Manual.

—6—

Page 6
Image 6
Bryant 552A warranty Accessory Usage Guideline, Required for LOW-AMBIENT LONG-LINE SEA Coast