Bryant 575B, 575C, 541A dimensions Iii. Start-Up, Cooling, Heating

Models: 541A 575B 575C

1 28
Download 28 pages 37.98 Kb
Page 28
Image 28
III. START-UP

III. START-UP

CHECK INDOOR FAN SPEED AND RECORD. _______________

CHECK OUTDOOR FAN SPEED AND RECORD. ________________

AFTER AT LEAST 10 MINUTES RUNNING TIME, RECORD THE FOLLOWING MEASUREMENTS:

 

 

COOLING

HEATING

OIL PRESSURE

 

__________________

__________________

SUCTION PRESSURE

 

__________________

__________________

SUCTION LINE TEMP

 

__________________

__________________

DISCHARGE PRESSURE

 

__________________

__________________

DISCHARGE LINE TEMP

 

__________________

__________________

ENTERING OUTDOOR AIR

 

__________________

__________________

LEAVING OUTDOOR AIR TEMP

 

__________________

__________________

INDOOR ENTERING-AIR DB (dry bulb) TEMP

__________________

__________________

INDOOR ENTERING-AIR WB (wet bulb) TEMP

__________________

__________________

INDOOR LEAVING-AIR DB TEMP

 

__________________

__________________

INDOOR LEAVING-AIR WB TEMP

 

__________________

__________________

COMPRESSOR AMPS (L1/L2/L3)

_______ / _______

/ _______

_______ / _______ / _______

CHECK THE COMPRESSOR OIL LEVEL SIGHT GLASSES; ARE THE SIGHT GLASSES SHOWING OIL LEVEL IN VIEW? (Y/N)

NOTES:

______________________________________________________________________________________________________________

______________________________________________________________________________________________________________

______________________________________________________________________________________________________________

______________________________________________________________________________________________________________

______________________________________________________________________________________________________________

______________________________________________________________________________________________________________

______________________________________________________________________________________________________________

______________________________________________________________________________________________________________

______________________________________________________________________________________________________________

______________________________________________________________________________________________________________

______________________________________________________________________________________________________________

______________________________________________________________________________________________________________

COOLINGCUT ALONG DOTTED LINE

HEATINGCUT ALONG DOTTED LINE

Copyright 2004 Bryant Heating & Cooling Systems

Printed in U.S.A.

10-05A

CL-2

CATALOG NO. 5357-506

Page 28
Image 28
Bryant 575B, 575C, 541A dimensions Iii. Start-Up, Cooling, Heating