DIMENSIONS

MODELS BW4 and BW5

GAGE

1 14SUPPLY

C

B

 

CONTROL

 

 

36

1 14

RETURN

TANKLESS

34ASME

HEATER

RELIEF

12N.P.T.

VALVE

19 58

FRONT

9 A

SIDEREAR

DIMENSIONS (In.)

UNIT SIZE

A

B

C

 

 

 

 

140

17-3/4

6

9-3/4

210

21

6

11-3/8

 

 

 

 

280

24-1/4

6

13

 

CLEARANCES (In.)

 

 

RIGHT SIDE

 

16*

 

 

 

LEFT SIDE

 

16*

TOP

 

16*

 

 

 

BACK

 

16*

FRONT

 

16†

FLUE

 

18*

* Clearance 18 in. for BW5.

† Service clearance requirement 24 in.

RATINGS AND PERFORMANCE

 

 

 

 

**HEAT-

NET

FIRING

 

 

 

 

 

 

 

 

 

ING CA-

I=B=R

 

 

 

 

 

 

 

 

INPUT

PACITY

RATING

RATE

 

MINIMUM CHIMNEY

 

 

 

BOILER MODEL NO.

NO. SEC.

*MBH

*MBH

*MBH

+GPH

A.F.U.E. ++

SIZE/ HEIGHT

DIMENSIONS - IN.

WITH TANKLESS

WITHOUT TANKLESS

 

 

 

 

 

 

 

 

 

 

COIL

COIL

 

 

 

 

 

 

 

A

B

C

BW5BAH091

BW4BAH091

3

91

80

70

0.65

86.3

8-in. x 8-in. x 15 ft

14-1/2

6

8

 

 

 

 

 

 

 

 

 

 

 

 

BW5BAH105

BW4BAH105

3

105

92

80

0.75

85.2

8-in. x 8-in. x 15 ft

14-1/2

6

8

 

 

 

 

 

 

 

 

 

 

 

 

BW5BAH140

BW4BAH140

3

140

119

103

1

83.4

8-in. x 8-in. x 15 ft

14-1/2

6

8

 

 

 

 

 

 

 

 

 

 

 

 

BW5BAH126

BW4BAH126

4

126

111

97

0.9

86.0

8-in. x 8-in. x 15 ft

17-3/4

6

9-5/8

 

 

 

 

 

 

 

 

 

 

 

 

BW5BAH175

BW4BAH175

4

175

150

130

1.25

83.9

8-in. x 8-in. x 15 ft

17-3/4

6

9-5/8

 

 

 

 

 

 

 

 

 

 

 

 

BW5BAH210

BW4BAH210

4

210

178

155

1.5

82.4

8-in. x 8-in. x 15 ft

17-3/4

6

9-5/8

 

 

 

 

 

 

 

 

 

 

 

 

BW5BAH168

BW4BAH168

5

168

147

128

1.2

86.5

8-in. x 8-in. x 15 ft

21

6

11-1/2

 

 

 

 

 

 

 

 

 

 

 

 

BW5BAH245

BW4BAH245

5

245

209

182

1.75

83.6

8-in. x 8-in. x 15 ft

21

6

11-1/2

 

 

 

 

 

 

 

 

 

 

 

 

BW5BAH280

BW4BAH280

5

280

236

205

2

82.0

8-in. x 8-in. x 20 ft

21

6

11-1/2

 

 

 

 

 

 

 

 

 

 

 

 

*MBH = 1,000 BTU per hour / BTU = British Thermal Unit.

**Heating Capacity is based on a 13 percent C02 with a –0.02 in. wc and a #1 smoke or less. Testing was done in accordance with the D.O.E. (Department of Energy) test procedure.

+GPH = Gallons per hour oil at 140,000 BTU per gallon.

++A.F.U.E. = Annual Fuel Utilization Efficiency based upon D.O.E. test procedure.

As an Energy Star Partner, the manufacturer has determined that this product meets Energy Star guidelines for Energy Efficiency.