BW9AAN000075AAAA
|
|
| B |
|
| W |
| 9 |
| A |
|
| A |
| N |
| 000 |
|
| 075 |
| A |
|
| A |
|
| AA |
| |||||||||||
B — Boiler |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Variations | ||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| AA — Standard | |||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Type of System |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Series |
|
|
| ||||||
|
| W — Water |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||||
|
| S — Steam |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| A — Original | |||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
Combustion/Ignition |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Labeling |
|
|
| |||||||||||
1 | — Natural Draft/Standing Pilot |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||||||||||
2 | — Natural Draft/Electronic |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| A — Common Unit |
|
|
| |||||||||||||
3 | — Induced Draft/Electronic |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| G — Canada Only (oil) |
|
|
| |||||||||||||
4 | — Oil Burner/Without Tankless Coil |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||||||||
5 | — Oil Burner/With Tankless Coil |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||||
9 | — 90% Direct Vent/Sealed |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||||
| Combustion |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
| Model Code |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
| Electrical |
|
|
|
|
|
|
|
|
|
|
| Heating Size |
|
|
| |||||||||||||||
|
|
|
|
|
|
|
|
|
| A 110 to 125 60 Hz |
|
|
|
|
|
|
|
|
|
|
| Btu Input (x 1000) |
|
|
| |||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
| Fuel |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
|
| H — Heating Oil |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
|
| N — Natural Gas |
|
|
|
|
|
|
| Cooling |
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||
|
|
|
|
|
|
|
|
|
|
|
| P — Propane |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
BOILER ACCESSORIES |
|
|
|
BW1/BW2 |
|
DESCRIPTION | PART NO. |
|
|
Filtrol Package (Up to 75,000 Btuh Input) | KBAFP0101DNK |
|
|
Filtrol Package (Up to 150,000 Btuh Input) | KBAFP0201DNK |
|
|
Filtrol Package (Over 150,000 Btuh Input) | KBAFP0301DNK |
|
|
High Limit Control | KBAHL0101DNK |
|
|
Combustible Floor Base (2 thru 6 section models) | KBASB0301DNK |
|
|
Combustible Floor Base (7 thru 9 section models) | KBASB0401DNK |
|
|
Zoning Valve 3/4 in. | KBAZV0101DNK |
|
|
Zoning Valve 1 in. | KBAZV0201DNK |
|
|
Gas Conversion Kit Natural to Propane (After 1799V) | KBANP0201DNK |
|
|
Gas Conversion Kit Propane to Natural | KBAPN0201DNK |
|
|
NOTE: There was never a Natural to Propane conversion kit for BW/BS boiler prior to 1799V. |
|
|
|
BW3 |
|
DESCRIPTION | PART NO. |
|
|
Filtrol Package (Up to 75,000 Btuh Input) | KBAFP0101DNK |
|
|
Filtrol Package (Up to 150,000 Btuh Input) | KBAFP0201DNK |
|
|
Filtrol Package (Over 150,000 Btuh Input) | KBAFP0301DNK |
|
|
High Limit Control | KBAHL0101DNK |
|
|
Combustible Floor Base (2 thru 6 section models) | KBASB0301DNK |
|
|
Combustible Floor Base (6 thru 7 section models) | KBASB0401DNK |
|
|
Zoning Valve 3/4 in. | KBAZV0101DNK |
|
|
Zoning Valve 1 in. | KBAZV0201DNK |
|
|
Gas Conversion Kit Natural to Propane (After 1799V) | KBANP0201DNK |
|
|
Gas Conversion Kit Propane to Natural | KBAPN0201DNK |
|
|
NOTE: There was never a Natural to Propane conversion kit for BW/BS boiler prior to 1799V. |
|
|
|
BS1/BS2 |
|
DESCRIPTION | PART NO. |
|
|
Combustible Floor Base (2 thru 6 section models) | KBASB0301DNK |
|
|
See notes on page 3.