Bryant BW2, BW4B, BS1, BW1, BS2, BW5B, BW3, BW9 manual Models BW4 and BW5

Models: BW1 BS1 BW9 BW4B BW5B BW3 BS2 BW2

1 16
Download 16 pages 33.61 Kb
Page 13
Image 13

MODELS BW4 and BW5

The modern design and attractive appearance of the models BW4 and BW5 Oil-Fired Water Boilers make them ideal for installation in any area. The boilers are shipped fully assembled and wired, including all controls (except barometric draft regulator). The compact 22-gage steel cabinet has a baked-on enamel paint finish for durability. A 1-in. layer of thermal insulation is applied inside the jacket for protection and thermal efficiency. The flame retention head burner

provides efficient fuel usage. A wet base cast iron block with thermal pins surrounds the combustion area for better heat transfer from flue gases to water.

FEATURES

BAROMETRIC DRAFT CONTROL—The factory supplied barometric draft control can easily be installed in the vent pipe for optimum draft and combustion efficiency.

CONTROLS—Factory-wired controls on units with tankless hot water coil include a triple aquastat relay with high/low limit protection and circulator control.

COMBINATION TRANSFORMER AQUASTAT—A24-v transformer is combined with the aquastat assembly. The transformer will supply power efficient to power a 3-zone system on BW5 models. Factory installed combination pressure/ temperature gage and a pressure relief valve.

COIL OPTIONS—Units are available with or without tankless heater coil. The coil provides a supply of hot water for normal domestic purposes or an accessory tankless heater coil can be added later.

FACTORY INSTALLED FEATURES—A factory-installed drain is provided should the boiler ever need to be drained. Oil primary control prevents boiler in operation in the event of flame loss.

SECTIONS TESTED—Each section is hydrostatically tested to 50 psig. Individual sections are tested to 125 psig at factory. Assembled sections are tested to 75 psig at the factory. The maximum allowable pressure is 50 psig for hot water boilers.

EASE OF INSTALLATION—Circulator is shipped pre-wired with 6 ft bx conduit for easy installation for supply side pumping.

WARRANTY—The cast-iron sections are covered by a non- prorated 20-year warranty on the entire assembly. Oil burner and circulator pump covered by 3-year warranty. All other parts are covered by a 1-year limited warranty.

SOLENOID OIL VALVE—This provides cleaner burning and quieter operation. Valve is included on all burner types.

SWING BURNER DOOR—This unique design offers uninhibited access for set-ups, service, and maintaining the burner. Routine cleaning is also much easier.

SPECIFICATIONS

UNIT SIZE

GENERAL DATA

120

181

239

 

Sections — Fine Grain Cast Iron

No.

3

4

5

 

 

 

 

 

 

 

 

 

Water Capacity

Gal

9.6

11.6

13.7

 

 

Combustion Chamber Target Wall

 

 

Ceramic Fiber

 

 

 

 

 

 

 

 

 

 

Draft Regulator

 

 

Furnished

 

 

 

 

 

 

 

 

 

 

OIL BURNER

 

 

 

 

 

 

 

 

 

 

 

 

Type Manufacturer/Model

Oil Pump

Fuel Type

Rated Load Amps

CONTROLS

Beckett/Model AFG Flame Retention Head Burner

Single Stage

No. 1 or 2 Fuel Oil

3 Amps

 

Combination Control

Without Heater

High Limit, Circulator Relay, & Cad. Cell Relay

 

 

 

 

 

 

 

 

With Heater

High & Low Limit, Circulator Relay, & Cad. Cell Relay

 

 

Pressure/Temperature Gage

Psig

0–60

 

 

 

°F

60–260

 

 

 

 

 

 

 

ASME Pressure Relief Valve

Psig

30

 

 

 

 

 

 

 

CIRCULATOR

 

 

 

 

 

 

 

 

 

Taco

Model

007

 

 

 

 

 

 

 

Full Load Amps

 

0.70

 

 

Flange Size FPT

In.

1-1/4

 

 

 

 

 

 

—13—

Page 13
Image 13
Bryant BW2, BW4B, BS1, BW1, BS2, BW5B, BW3, BW9 manual Models BW4 and BW5