CONNECTION DIAGRAM

 

Line voltage factory wiring

 

 

 

 

 

 

 

 

 

 

Class 2 low voltage factory wiring

 

 

 

 

 

 

 

 

 

 

Class 2 low voltage field wiring

 

 

 

 

 

 

 

 

 

 

1. For continued fire protection, use specified UL

COLOR CODE

 

 

 

 

 

 

 

DAMPER ELECTRONIC

listed/CSA Certified line fuse.

 

 

 

 

 

 

 

 

 

 

ASSEMBLY

2. If any of the original wire, as supplied, must be

BLK

BLACK

 

 

 

 

 

 

 

 

 

 

replaced,use the same equivalent wire.

BLU

BLUE

 

 

BLK

 

 

J3

 

 

 

A2

3. Field wiring must comply with applicable codes,

BRN

BROWN

Damper motor

 

 

 

 

 

 

 

GRN

GREEN

M3

 

1

2

 

 

 

 

 

ordinances and regulations.

GRY GRY

 

 

BLK

5

4

3

2

1

2

1

4. Remote controls available. See instruction

ORG

ORANGE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

manual. (class 2 circuit)

RED

RED

 

 

 

J2

 

 

 

 

 

J1

5. Furnace fan circuit must be class 2 circuit only.

WHT

WHITE

 

 

 

 

 

 

 

 

 

 

YEL

YELLOW

 

 

 

S1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ERV / HRV

Exhaust fan motor

GRN

M1

 

 

T1

Door interlock

 

 

 

 

120V

 

 

switch

 

 

 

BLK

 

(magnetically

 

 

 

 

 

 

 

Defrost temperature

BLU

90V

24V class 2

actuated reed

to

R1

sensor

68V

 

 

switch)

 

 

RED

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

9.5V

WHT

WHT

 

 

 

WHT neutral

class 2

 

 

 

 

 

 

 

 

Field wiring

 

 

 

 

 

 

remote control

 

 

Y

BRN

 

 

(see notes 3, 4)

 

 

 

 

 

 

 

 

Y

BRN

 

 

 

 

 

 

 

 

 

 

RED

BLK

BLK

 

 

 

GRN

YEL

 

 

 

 

 

BLU

 

 

 

 

 

BRN

1

 

 

10

 

 

2

J5

J8

9

 

 

3

 

J11

8

 

 

 

 

J13

7

 

Exhaust fan motor capacitor C1

Supply fan motor capacitor C2

Supply fan motor M2

BLK

2

J7

5 4

 

3

2 1

1 2

 

 

 

ICP

6

Override switch

 

1

 

 

 

 

J12

 

 

 

5

(optional; see notes

BLK

 

 

 

 

 

 

 

 

 

 

4

3, 4)

 

 

 

 

 

 

 

1

2

3

4

5

3

 

 

 

 

J9

 

 

 

2

 

 

 

 

 

 

 

 

 

 

 

 

1

 

BLK

2

 

4

3

2

1

 

 

 

 

 

J14

 

BLK

J6

 

 

 

 

 

 

 

1

 

 

 

 

 

 

 

 

 

 

 

 

1

See note 1

 

2

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

J4

J10

 

 

 

 

 

 

 

 

 

 

BLK

3

F1

 

 

 

 

 

 

 

 

 

 

BLU

 

 

 

 

 

 

 

 

 

 

Furnace blower interlock

 

 

 

 

 

 

ELECTRONIC ASSEMBLY

 

BRN

 

 

 

 

 

 

 

 

 

 

J14-1 : NO

Connect to R at Furnace / Fan Coil

 

 

 

 

 

 

 

 

 

 

 

 

J14-2 : COM

Connect to G at Furnace / Fan Coil

GRN

 

 

 

BLK

WHT

 

 

 

 

 

J14-3 : NC

Connect to G at Thermostat

 

 

 

 

 

 

 

 

 

 

(see notes 3 , 5)

 

 

120V, 60Hz

W1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

GRN

 

 

 

 

 

MODELS

HRVCCSHA1100, HRVCCSVA1100,

ERVCCSHA1100, ERVCCSVA1100,

K5

K2

K3

K1

MODE

M1 "Supply"

M2 - "Exhaust"

DAMPER

0

0

0

0

OFF

OFF

OFF

Closed

1

0

1

1

Exchange low speed

LO

LO

Opened

1

1

1

1

Exchange high speed

HI

HI

Opened

1

1

1

0

Circulation high speed

HI

OFF

Closed

1

1

1

0

Defrost

HI

OFF

Closed

A07118

Fig. 17 - ERV / HRV Wiring Diagram

12

Page 12
Image 12
Bryant ERVBBSVA1100 installation instructions ERV / HRV Wiring Diagram