RIDGID SP-330D Performance Curve, Performance Chart, Pump Installation, Specifications, Motor

Models: SP-330D SP-330 SP500A SP-500

1 28
Download 28 pages 26.64 Kb
Page 6
Image 6
Specifications
! WARNING

SP-330, SP-330D, SP-500, SP-500A Submersible Sump Pumps

Specifications

Motor:

 

Type

Shaded Pole

Rating

120V, Single Phase

 

1/3 HP, 9.5 Amps

 

1/2 HP, 10 Amps

Pump

 

1/3 HP

3100 GPH @ 0 Ft.

1/2 HP

4400 GPH @ 0 Ft.

Liquid temperature range ....

40F to 120F

Cut in level

9”

Cut out level

4”

Pump must be plugged into an outlet recepta- cle that includes a Ground Fault Circuit Interrupter (GFCI) (Figure 1).

Always disconnect the power source before attempting to install, service, relocate, or main- tain the pump. Never handle a pump or pump motor with wet hands or when standing on wet or damp surface or in water.

Installation

1.Construct a sump pit from concrete, steel, or plas- tic that is 24” deep and at least 11” in diameter (Figure 2 next page). If the sump already exists,

Performance Curve

 

25

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(Feet)

20

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SP-500

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SP-300

 

 

 

 

 

15

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SP-300D

 

 

 

Discharge

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SP-500A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

10

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

1000

2000

3000

4000

5000

6000

 

 

 

 

 

 

 

 

Gallons Per Hour

 

 

 

 

 

 

 

Performance Chart

 

 

 

 

 

 

 

 

 

Model

 

Discharge Head

 

 

0’

 

 

 

5’

 

10’

15’

SP-330

 

Gallons/Hour

3100

3000

 

2700

1680

SP-330D

Gallons/Hour

3100

3000

 

2700

1680

SP-500

 

Gallons/Hour

4400

4100

 

3200

2000

SP-500A

Gallons/Hour

4400

4100

 

3200

2000

Pump Installation

!DANGER

Pump should only be used to pump clear water. Do not use to pump fluids such as gaso- line, fuel oil, or kerosene. Do not use in a flam- mable or explosive atmosphere. Improper use could result in personal injury and/or death.

Motor:PumpInstallation To prevent property damage, serious injury, or death, proper installation of the pump is required. The following procedures should be followed:

make sure it is the proper size.

2.Make sure the electrical outlet is grounded and is rated for 115 volts and at least 15 amps. The out- let must be protected by a Ground Fault Circuit Interrupter (GFCI).

! WARNING Use of a grounded receptacle that is protected by a GFCI reduces risk of a fatal electrical shock.

3.Inspect the power cord and plug for damage. If the plug is missing the grounding prong or the cord is damaged, do not install the pump until the cord has been replaced.

(Model SP-330D Diaphragm Switch only)

4.Remove the two fasteners in the cast iron volute near the discharge area. Align the hole with the diaphragm switch and replace the fasteners with- out over tightening.

Figure 2 – Submersible Pump Installation

4

Ridge Tool Company

Page 6
Image 6
RIDGID SP-330D Performance Curve, Performance Chart, Pump Installation, Specifications, Motor, Danger, Ridge Tool Company